MEASUREMENT OF ACOUSTIC NOISE DURING MR-IMAGING - EVALUATION OF 6 WORST-CASE PULSE SEQUENCES

被引:56
作者
SHELLOCK, FG
MORISOLI, SM
ZIARATI, M
机构
[1] UNIV CALIF LOS ANGELES, SCH MED, DEPT RADIOL SCI, LOS ANGELES, CA USA
[2] RESONANCE TECHNOL, VAN NUYS, CA USA
[3] ST JOHNS HOSP, DEPT IMAGING, SANTA MONICA, CA USA
关键词
MAGNETIC RESONANCE (MR); BIOLOGICAL EFFECTS; QUALITY ASSURANCE; TECHNOLOGY;
D O I
10.1148/radiology.191.1.8134603
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess acoustic noise levels for ambient noise and magnetic resonance (MR) imaging at 1.5 T during use of six ''worst-case'' pulse sequences. MATERIALS AND METHODS: Acoustic noise measurements were obtained at the entrance, center, and exit of the magnet bore of the MR system by means of a specially modified device that is unaffected by electromagnetic radiation. RESULTS: The highest ambient noise level was 73 dB at both the entrance and exit of the magnet bore (A-weighted scale). The highest noise levels during MR imaging occurred during use of a gradient-echo (GRE) pulse sequence and was 102 dB at the entrance and exit of the magnet bore and 103 dB at the center (A-weighted scale). CONCLUSIONS: MR imaging performed with the worst-case pulse sequences did not produce noise levels that exceeded federal guidelines. Noise levels were, however, high enough to impair oral communication and annoy patients. Thus, techniques to attenuate acoustic noise and allow improved operator-patient communication should be used during MR imaging, especially during use of GRE pulse sequences.
引用
收藏
页码:91 / 93
页数:3
相关论文
共 10 条
[1]   POTENTIAL HEARING-LOSS RESULTING FROM MR IMAGING [J].
BRUMMETT, RE ;
TALBOT, JM ;
CHARUHAS, P .
RADIOLOGY, 1988, 169 (02) :539-540
[2]   OPERATIONAL SAFETY ISSUES IN MRI [J].
GANGAROSA, RE ;
MINNIS, JE ;
NOBBE, J ;
PRASCHAN, D ;
GENBERG, RW .
MAGNETIC RESONANCE IMAGING, 1987, 5 (04) :287-292
[3]   REDUCTION OF SOUND LEVELS WITH ANTINOISE IN MR IMAGING [J].
GOLDMAN, AM ;
GOSSMAN, WE ;
FRIEDLANDER, PC .
RADIOLOGY, 1989, 173 (02) :549-550
[4]   ACOUSTIC ANALYSIS OF GRADIENT-COIL NOISE IN MR IMAGING [J].
HURWITZ, R ;
LANE, SR ;
BELL, RA ;
BRANTZAWADZKI, MN .
RADIOLOGY, 1989, 173 (02) :545-548
[5]  
MELNICK W, 1979, HDB NOISE CONTROL, P1
[6]  
MILLER LE, 1979, HDB NOISE CONTROL, P2
[7]  
ROBINSON DW, 1976, EFFECTS NOISE HEARIN, P383
[8]  
SHELLOCK FG, 1992, REV MAGN RESON IMAGI, V4, P21
[9]  
SHELLOCK FG, IN PRESS MAGNETIC RE
[10]  
1988, FED REGISTER, V53, P7575