EFFECTS OF ANTERIOR VERTEBRAL GRAFTING ON THE TRAUMATIZED LUMBAR SPINE AFTER PEDICLE SCREW-PLATE FIXATION

被引:34
作者
MAIMAN, DJ
PINTAR, F
YOGANANDAN, N
REINARTZ, J
机构
[1] MED COLL WISCONSIN,DEPT NEUROSURG,9200 W WISCONSIN AVE,MILWAUKEE,WI 53226
[2] MED COLL WISCONSIN,DEPT NEUROSURG,MILWAUKEE,WI 53226
关键词
LUMBAR SPINE; FUSION; FRACTURE; BIOMECHANICS; PEDICLE FIXATION;
D O I
10.1097/00007632-199312000-00010
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
This study was conducted to determine the effects of corpectomy and anterior strut grafting on the biomechanics of traumatized lumbar spine after pedicle screw-plate fixation. Eight lumbar spines were loaded until fracture (initial cycle) and then reloaded to the same deformation (injury cycle). After transpedicular fixation, spines were again loaded (fixation cycle). Partial corpectomy of the fractured body and anterior strut grafting were accomplished; the spine reloaded (strut cycle). Spine angles were measured and biomechanical strength and kinematic parameters analyzed. Load-deformation relationships were similar for fixation and strut cycles until maximum load; at failure, loads were higher for the former (P < 0.05), however. Alignment was improved by stabilization or stabilization plus anterior grafting (P < 0.05). Vertebral height was best maintained by grafting as an adjunct to pedicle fixation (P < 0.05). Kinematics were largely unaffected by grafting, except for reduced motion at the posterior vertebral targets between the fixated levels (P < 0.05). The strength of the fixated spine is relatively unchanged by corpectomy and anterior grafting; alignment may be improved in the latter group.
引用
收藏
页码:2423 / 2430
页数:8
相关论文
共 25 条
[1]  
Aebi M., Etter C., Kehl T., Thalgott J., The internal skeletal fixation system: A new treatment of thoracolumbar fractures and other spinal disorders, Clin Orthop, 227, pp. 30-43, (1988)
[2]  
Carl A.L., Tromanhauser S.G., Roger D.J., Pedicle screw instrumentation for thoracolumbar burst fractures and fracture- dislocations, Spine, 17, pp. S317-S524, (1992)
[3]  
Chang K.W., Dewei Z., McAfee P.C., Warden K.E., Farey I., Gurr K., A comparative biomechanical study of spinal fixation using the combination spinal rod-plate and transpedicular screw fixation system, J Spinal Disorders, 1, pp. 257-266, (1989)
[4]  
Denis F., Spinal instability as defined by the three-column concept in acute spine trauma, Clin Orthop, 189, pp. 65-76, (1984)
[5]  
Dick W., The “fixateur interne” as a versatile implant for spine surgery, Spine, 12, pp. 882-900, (1987)
[6]  
Gurr K.R., McAfee P.C., Shih C.M., Biomechanical analysis of anterior and posterior instrumentation systems after corpectomy, J Bone Joint Surg, 70, pp. 1182-1191, (1988)
[7]  
Krag M.H., Beynnon B.D., Pope M.H., Frymoyer J.W., Haugh C.D., Weaver D.L., An internal fixator for posterior application to short segments of the thoracic, lumbar, or lumbosacral spine: Design and testing, Clin Orthop, 203, pp. 75-98, (1986)
[8]  
Krag M.H., Beynnon B.D., Pope M.H., Decoster T.A., Depth of insertion of transpedicular vertebral screws into human vertebrae: Effect upon screw-vertebra interface strength, J Spinal Disorders, 1, pp. 287-294, (1989)
[9]  
Larson S.J., Holst R.A., Hemmy D.C., Sances A., The lateral extracavitary approach to traumatic lesions of the thoracic and lumbar spine, J Neurosurg, 45, pp. 628-637, (1976)
[10]  
Larson S.J., Unstable thoracic fractures: Treatment alternatives and the role of the neurosurgeon, Clin Neurosurg, 27, pp. 624-640, (1980)