SESTAMIBI PARATHYROID IMAGING

被引:136
作者
MCBILES, M
LAMBERT, AT
COTE, MG
KIM, SY
机构
[1] Nuclear Medicine Service, Department of Radiology, Fitzsimons Army Medical Center, Aurora, CO
关键词
D O I
10.1016/S0001-2998(95)80012-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Since the introduction of technetium-99m (Tc-99m) sestamibi (hexakis-2-methoxyisobutyl isonitrile) as a parathyroid imaging agent in 1989, many investigators using several different imaging protocols have reported uniformly excellent results for localization of parathyroid adenomas. Exact localization of hyperplastic parathyroid glands has not met with as much success. However, the results of multiple comparative studies suggest that the diagnostic utility of sestamibi protocols equals or exceeds other noninvasive, nonscintigraphic imaging strategies, including high-resolution ultrasound, computed tomography, and magnetic resonance imaging. Two different, but not necessarily mutually exclusive imaging strategies have been used: subtraction imaging using iodine-123 (I-123) or (TC)-T-99m sodium pertechnetate as the thyroid agent and sestamibi as a thyroid-parathyroid agent, and sestamibi dual-phase imaging, which takes advantage of differential washout of sestamibi from thyroid and parathyroid tissue, Sestamibi subtraction imaging has been shown to have greater sensitivity for abnormal parathyroid glands compared with thallium-201 subtraction imaging using pooled data, 87% versus 71%, respectively. Dual-phase sestamibi imaging protocols are much more variable in their conduct and have a much greater variability in sensitivity, 43% to 98%, but with a pooled sensitivity of 73%. Data suggest that dual phase techniques are at least as sensitive, and in optimized protocols, superior to, thallium-201 subtraction techniques. This superiority is attributed to the favorable washout kinetics of sestamibi and the superior imaging characteristics of the Tc-99m label. Specificity and positive predictive value for both sestamibi techniques are very high, typically greater than 90% and at least equal to thallium-subtraction protocols, although specificity may be slightly lower for sestamibi subtraction techniques. Therefore, sestamibi protocols are the scintigraphic procedure of choice for parathyroid imaging. Dual-phase sestamibi protocols are more robust and lend themselves to single photon emission computer tomography (SPECT) imaging, and may be followed sequentially by subtraction techniques if results are inconclusive, Despite the excellent results of sestamibi parathyroid imaging, it is unclear whether this accuracy can compete with the even better success of an experienced surgeon in initial surgeries for hyperparathyroidism, and routine preoperative imaging before initial surgery is still controversial, However, sestamibi parathyroid imaging is an excellent addition to a correlative imaging approach in reoperations for persistent and recurrent hyperparathyroidism.
引用
收藏
页码:221 / 234
页数:14
相关论文
共 61 条
[1]
DIAGNOSIS OF RECURRENT HYPERPARATHYROIDISM - COMPARISON OF MR IMAGING AND OTHER IMAGING TECHNIQUES [J].
AUFFERMANN, W ;
GOODING, GAW ;
OKERLUND, MD ;
CLARK, OH ;
THURNHER, S ;
LEVIN, KE ;
HIGGINS, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (05) :1027-1033
[2]
INITIAL FAILURE OF SURGICAL EXPLORATION IN PATIENTS WITH PRIMARY HYPERPARATHYROIDISM [J].
AUGUSTE, LJ ;
ATTIE, JN ;
SCHNAAP, D .
AMERICAN JOURNAL OF SURGERY, 1990, 160 (04) :333-336
[3]
BILLOTEY C, 1994, J NUCL MED, V35, P1631
[4]
BOCKISCH A, 1994, J NUCL MED S, V35, P5
[5]
BRASSEUR F, 1992, EUR J NUCL MED, V19, P679
[6]
BRUINING HA, 1987, SURGERY, V101, P562
[7]
PARATHYROID SCINTIGRAPHY WITH I-123 AND (99M)TC-SESTAMIBI - IMAGING FINDINGS [J].
BURKE, GJ ;
WEI, JP ;
BINET, EF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (06) :1265-1268
[8]
BURN SC, 1994, S DAK J MED, V47, P202
[9]
CASARA D, 1991, European Journal of Nuclear Medicine, V18, P581
[10]
CASAS AT, 1994, AM SURGEON, V60, P12