STIR IMAGING OF SYNTHETIC VASCULAR GRAFT INFECTION

被引:9
作者
HANSEN, ME [1 ]
YUCEL, EK [1 ]
WALTMAN, AC [1 ]
机构
[1] MASSACHUSETTS GEN HOSP,DEPT RADIOL,BOSTON,MA 02114
关键词
GRAFT INFECTION; MAGNETIC RESONANCE IMAGING;
D O I
10.1007/BF02603034
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Nine patients with suspected prosthetic vascular graft infection were studied with axial spin echo (SE) and short TI inversion recovery (STIR) magnetic resonance imaging. Images were assessed for presence and extent of abnormality. All patients had either surgical (8/9) or bacteriologic (6/9) confirmation of infection. STIR images better defined the extent of infection and had greater fat-fluid contrast than SE images in 6/9 studies. In 3 cases with peri-graft fluid alone, T2-weighted images had slightly greater contrast, although the STIR images were still diagnostic. STIR imaging can offer improved accuracy in evaluation of suspected prosthetic graft infection when used in conjunction with SE techniques.
引用
收藏
页码:30 / 36
页数:7
相关论文
共 30 条
[1]  
Vogelzang R.L., Limpert J.D., Yao J.S.T., Detection of prosthetic vascular complications: Comparison of CT and angiography, AJR, 148, pp. 819-823, (1987)
[2]  
Low R.N., Wall S.D., Jeffrey R.B., Sollitto R.A., Reilly L.M., Tierney L.M., Aortoenteric fistula and perigraft infection: Evaluation with CT, Radiology, 175, pp. 157-162, (1990)
[3]  
Wolson A.H., Kaupp H.A., McDonald K., Ultrasound of arterial graft surgery complications, AJR, 133, pp. 869-875, (1979)
[4]  
Yashar J.J., Baxter J.C., Burnard R.J., Weyman A.K., Yashar J., Ultrasonic investigation of infected vascular prostheses, Int Surg, 64, 3, pp. 51-53, (1979)
[5]  
Dries D.J., Alazraki N., Lawrence P.F., Murphy K.M., Kercher J., Datz F.L., Christian P., Taylor A., Detection of acute synthetic vascular graft infection with 111 In-labeled leukocyte scanning: An animal study, AJR, 145, pp. 1053-1056, (1985)
[6]  
Williaon, Boyd C.M., Read R.C., Thompson B.W., Barnes R.W., Shah H.R., Balachandran S., Ferris E.J., 111 Inlabeled leukocytes in the detection of prosthetic vascular graft infections, AJR, 147, pp. 173-176, (1986)
[7]  
Brunner M.C., Mitchell R.S., Baldwin J.C., James D.R., Olcott C., Mehigan J.T., McDougall I.R., Miller D.C., Trosthetic graft infection: Limitations of indium white blood cell scanning, J. Vasc Surg, 3, pp. 42-48, (1986)
[8]  
Mark A.S., McCarthy S.M., Moss A.A., Price D., Detection of abdominal aortic graft infection: Comparison of CT and In-labled white blood cell scans, AJR, 144, pp. 315-318, (1985)
[9]  
Justich E., Amparo E.G., Hricak H., Higgins C.B., Infected aortoiliofemoral grafts: Magnetic resonance imaging, Radiology, 154, pp. 133-136, (1985)
[10]  
Auffermann W., Olofsson P., Stoney R., Higgins C.B., MR imaging of complications of aortic surgery, JCAT, 11, pp. 982-989, (1987)