THE IMPACT OF THE ISIS EXPERIMENT ORDER ON SPATIAL CONTAMINATION

被引:32
作者
BURGER, C
BUCHLI, R
MCKINNON, G
MEIER, D
BOESIGER, P
机构
[1] UNIV ZURICH,INST BIOMED ENGN & MED INFORMAT,CH-8044 ZURICH,SWITZERLAND
[2] SWISS FED INST TECHNOL,CH-8044 ZURICH,SWITZERLAND
关键词
D O I
10.1002/mrm.1910260204
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
When performing volume‐localized spectroscopy measurements, the amount of spatial contamination is an important quality criterion. With the ISIS localization technique contamination cannot only arise from the transition regions around the volume of interest, but also from remote regions of the sample. The latter contamination component is a consequence of inhomogeneous excitation pulses, if short repetition times TR are used. Its severity depends both on the order of the eight phase cycling experiments needed for an ISIS measurement, and on the ratio TR/T1. Here it is theoretically discussed from which regions of the sample contamination can arise for a specific phase cycling order. For the worst orders the contaminating regions are almost three times as large as for the optimal orders. The ratio for the effectively measured contamination, however, can be moderated in real experiments, because cancellation effects occur due to the phase distribution of the contaminating signals. 31P phantom experiments clearly demonstrate that contamination is present even if adiabatic excitation pulses are applied and that spatial contamination can be reduced to about a third by an optimal choice of the phase cycling order. Copyright © 1992 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:218 / 230
页数:13
相关论文
共 6 条
[1]   SWEEP-DIAGRAM ANALYSIS OF SELECTIVE ADIABATIC PULSES [J].
CONOLLY, S ;
NISHIMURA, D ;
MACOVSKI, A .
JOURNAL OF MAGNETIC RESONANCE, 1989, 83 (03) :549-564
[2]  
CONOLLY S, 1991, P SMRM, V10, P266
[3]   COMPUTER-SIMULATION OF MRS LOCALIZATION TECHNIQUES - AN ANALYSIS OF ISIS [J].
LAWRY, TJ ;
KARCZMAR, GS ;
WEINER, MW ;
MATSON, GB .
MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (03) :299-314
[4]   EXPERIMENTAL APPROACHES TO IMAGE LOCALIZED HUMAN P-31 NMR-SPECTROSCOPY [J].
LUYTEN, PR ;
GROEN, JP ;
VERMEULEN, JWAH ;
DENHOLLANDER, JA .
MAGNETIC RESONANCE IN MEDICINE, 1989, 11 (01) :1-21
[5]   IMAGE-SELECTED INVIVO SPECTROSCOPY (ISIS) - A NEW TECHNIQUE FOR SPATIALLY SELECTIVE NMR-SPECTROSCOPY [J].
ORDIDGE, RJ ;
CONNELLY, A ;
LOHMAN, JAB .
JOURNAL OF MAGNETIC RESONANCE, 1986, 66 (02) :283-294
[6]   A LINEAR CLASS OF LARGE-TIP-ANGLE SELECTIVE EXCITATION PULSES [J].
PAULY, J ;
NISHIMURA, D ;
MACOVSKI, A .
JOURNAL OF MAGNETIC RESONANCE, 1989, 82 (03) :571-587