IDENTIFICATION OF THE 3-ELEMENT WINDKESSEL MODEL INCORPORATING A PRESSURE-DEPENDENT COMPLIANCE

被引:31
作者
CAPPELLO, A [1 ]
GNUDI, G [1 ]
LAMBERTI, C [1 ]
机构
[1] UNIV BOLOGNA,DEIS,I-40136 BOLOGNA,ITALY
关键词
ARTERIAL SYSTEM; MATHEMATICAL MODEL; TOTAL ARTERIAL COMPLIANCE; AORTIC CHARACTERISTIC IMPEDANCE; NONLINEAR PRESSURE-VOLUME RELATIONSHIP; PARAMETER ESTIMATION; ENERGY BALANCE;
D O I
10.1007/BF02368323
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new one-step computational procedure is presented for estimating the parameters of the nonlinear three-element windkessel model of the arterial system incorporating a pressure-dependent compliance. The data required are pulsatile aortic pressure and flow. The basic assumptions are a steady-state periodic regime and a purely elastic compliant element. By stating two conditions, zero mean flow and zero mean power in the compliant element, peripheral and characteristic resistances are determined through simple closed form formulas as functions of mean values of the square of aortic pressure, the square of aortic flow, and the product of aortic pressure with aortic flow. The pressure across as well as the flow through the compliant element can be then obtained so allowing the calculation of volume variation and compliance as functions of pressure. The feasibility of this method is studied by applying it to both simulated and experimental data relative to different circulatory conditions and comparing the results with those obtained by an iterative parameter optimization algorithm and with the actual values when available. The conclusion is that the proposed method appears to be effective in identifying the three-element windkessel even in the case of nonlinear compliance.
引用
收藏
页码:164 / 177
页数:14
相关论文
共 19 条
[1]  
AVANZOLINI G, 1984, Automedica (London), V5, P37
[2]  
AVANZOLINI G, 1989, 11TH IEEE EMBS INT C, P1979
[3]  
AVANZOLINI G, 1992, 6 P MED C MED BIOL E, P227
[4]   STATIC ELASTIC PROPERTIES OF ARTERIAL WALL [J].
BERGEL, DH .
JOURNAL OF PHYSIOLOGY-LONDON, 1961, 156 (03) :445-&
[5]   MODIFIED ASYMMETRIC T-TUBE MODEL TO INFER ARTERIAL WAVE REFLECTION AT THE AORTIC ROOT [J].
BURATTINI, R ;
CAMPBELL, KB .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (08) :805-814
[6]   COMPUTER IDENTIFICATION OF MODELS FOR THE ARTERIAL TREE INPUT IMPEDANCE - COMPARISON BETWEEN 2 NEW SIMPLE-MODELS AND 1ST EXPERIMENTAL RESULTS [J].
BURATTINI, R ;
GNUDI, G .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1982, 20 (02) :134-144
[7]   TOTAL SYSTEMIC ARTERIAL COMPLIANCE AND AORTIC CHARACTERISTIC IMPEDANCE IN THE DOG AS A FUNCTION OF PRESSURE - A MODEL BASED STUDY [J].
BURATTINI, R ;
GNUDI, G ;
WESTERHOF, N ;
FIORETTI, S .
COMPUTERS AND BIOMEDICAL RESEARCH, 1987, 20 (02) :154-165
[8]  
CAPPELLO A, 1993, 1993 P INT C COMP CA, P385
[9]   QUANTITATIVE-EVALUATION OF THE SYSTEMIC ARTERIAL BED BY PARAMETER-ESTIMATION OF A SIMPLE-MODEL [J].
DESWYSEN, B ;
CHARLIER, AA ;
GEVERS, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1980, 18 (02) :153-166
[10]   CHARACTERISTIC IMPEDANCE OF THE PROXIMAL AORTA DETERMINED IN THE TIME AND FREQUENCY-DOMAIN - A COMPARISON [J].
DUJARDIN, JPL ;
STONE, DN .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1981, 19 (05) :565-568