FLOW-INJECTION DETERMINATION OF METHIONINE WITH AMPEROMETRIC DETECTION AT A STABLE MODIFIED ELECTRODE

被引:24
作者
COX, JA
DABEKZLOTORZYNSKA, E
机构
[1] Department of Chemistry, Miami University, Oxford, Ohio
关键词
D O I
10.1002/elan.1140030317
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glassy carbon electrode that is modified by electrodeposition of a film comprising mixed valence ruthenium oxide stabilized by cyano crosslinks catalyzes the oxidation of methionine at 0.92 V vs. Ag/AgCl. A linear calibration curve is obtained for flow injection amperometry over the range 0.6-180-mu-M with a 0.2 M K2SO4 carrier at pH 2, a 7.5-mu-L sample volume, and a 1.0 mL/min flow rate. The sensitivity is 20 +/- 0.3 nA/mu-M at a 0.07 cm2 electrode. With a single surface preparation, the sensitivity of the method remains constant over more than 3 weeks with daily use. The method also was used with carriers of the composition of common liquid chromatographic eluents such as various citrate-phosphate mixtures and a 0.1 M chloroacetic acid solution at pH 3.0 in 1% acetonitrile.
引用
收藏
页码:239 / 242
页数:4
相关论文
共 19 条
[1]   DUAL ELECTRODE LIQUID-CHROMATOGRAPHY DETECTOR FOR THIOLS AND DISULFIDES [J].
ALLISON, LA ;
SHOUP, RE .
ANALYTICAL CHEMISTRY, 1983, 55 (01) :8-12
[2]  
ALLISON LA, 1981, J LIQ CHROMATOGR, V222, P445
[3]   FLOW-INJECTION AMPEROMETRY OF CYSTEINE AND GLUTATHIONE AT AN ELECTRODE MODIFIED WITH A RUTHENIUM-CONTAINING INORGANIC FILM [J].
COX, JA ;
GRAY, TJ .
ELECTROANALYSIS, 1990, 2 (02) :107-111
[4]   FLOW-INJECTION AMPEROMETRIC DETERMINATION OF INSULIN BASED UPON ITS OXIDATION AT A MODIFIED ELECTRODE [J].
COX, JA ;
GRAY, TJ .
ANALYTICAL CHEMISTRY, 1989, 61 (21) :2462-2464
[5]   CHARACTERISTICS OF A GLASSY-CARBON ELECTRODE MODIFIED IN A MIXTURE OF OSMIUM-TETROXIDE AND HEXACYANORUTHENATE [J].
COX, JA ;
DAS, BK .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 233 (1-2) :87-98
[6]   STABLE MODIFIED ELECTRODES FOR FLOW-INJECTION AMPEROMETRY - APPLICATION TO THE DETERMINATION OF THIOCYANATE [J].
COX, JA ;
GRAY, T ;
KULKARNI, KR .
ANALYTICAL CHEMISTRY, 1988, 60 (17) :1710-1713
[7]   FLOW-INJECTION DETERMINATION OF NITRITE BY AMPEROMETRIC DETECTION AT A MODIFIED ELECTRODE [J].
COX, JA ;
KULKARNI, KR .
ANALYST, 1986, 111 (10) :1219-1220
[8]   COMPARISON OF INORGANIC FILMS AND POLY(4-VINYLPYRIDINE) COATINGS AS ELECTRODE MODIFIERS FOR FLOW-INJECTION SYSTEMS [J].
COX, JA ;
KULKARNI, KR .
TALANTA, 1986, 33 (11) :911-913
[9]   ELECTROCATALYTIC OXIDATION AND DETERMINATION OF ARSENIC(III) ON A GLASSY-CARBON ELECTRODE MODIFIED WITH A THIN-FILM OF MIXED-VALENT RUTHENIUM(III, II) CYANIDE [J].
COX, JA ;
KULESZA, PJ .
ANALYTICAL CHEMISTRY, 1984, 56 (06) :1021-1025
[10]   ANALYSIS OF HEPATIC REDUCED GLUTATHIONE, CYSTEINE AND HOMOCYSTEINE BY CATION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
DEMASTER, EG ;
SHIROTA, FN ;
REDFERN, B ;
GOON, DJW ;
NAGASAWA, HT .
JOURNAL OF CHROMATOGRAPHY, 1984, 308 (JUN) :83-91