ENERGY RESPONSE OF LIF, FILM AND A CHEMICAL DOSIMETER TO HIGH-ENERGY PHOTONS AND ELECTRONS

被引:8
作者
BISTROVIC, M
MARICIC, Z
GREENFIELD, MA
BREYER, B
DVORNIK, I
SLAUS, I
TOMAS, P
机构
[1] CENT INST TUMOURS & ALLIED DIS, YU-41000 Zagreb, YUGOSLAVIA
[2] INST RUDER BOSKOVIC, Zagreb, YUGOSLAVIA
[3] UNIV CALIF LOS ANGELES, DEPT RADIOL, LOS ANGELES, CA 90024 USA
关键词
D O I
10.1088/0031-9155/21/3/007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The physical responses of LiF, film and a chemical dosemeter in high energy photon and electron beams was studied. The response for film and the chemical dosemeter does not change significantly up to 42 MeV, while for LiF it decreases by about 10%. Analysis of calculations and measurements showed that this decrease could not be explained by existing theories.
引用
收藏
页码:414 / 421
页数:8
相关论文
共 9 条
[1]   ENERGY RESPONSE OF LIF, CAF2, AND LI2B407-MN TO HIGH ENERGY RADIATIONS [J].
ALMOND, PR ;
MCCRAY, K .
PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (02) :335-&
[2]  
[Anonymous], 1971, PHYS MED BIOL, V16, P379
[3]  
Berger M.J., 1964, Tech. Rep. NASA SP-3012
[4]   CAVITY IONISATION THEORY APPLIED TO SOLID STATE RADIATION DETECTORS [J].
BURLIN, TE ;
CHAN, FK .
BRITISH JOURNAL OF RADIOLOGY, 1967, 40 (475) :556-&
[5]   ENERGY RESPONSE OF LIF, CAF2 AND LI2B4O7 TO HIGH ENERGY RADIATIONS [J].
BURLIN, TE .
PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (03) :558-+
[6]  
DVORNIK I, 1969, HANDLING RADIATION A, P225
[7]   ENERGY-DEPENDENCE OF RESPONSE OF LITHIUM-FLUORIDE TLD RODS IN HIGH-ENERGY ELECTRON FIELDS [J].
HOLT, JG ;
EDELSTEIN, GR ;
CLARK, TE .
PHYSICS IN MEDICINE AND BIOLOGY, 1975, 20 (04) :559-570
[8]  
JOHNS HE, 1969, PHYSICS RADIOLOGY, P291
[9]   APPLICATIONS OF CAVITY THEORIES FOR ELECTRONS TO LIF DOSIMETERS [J].
PALIWAL, BR ;
ALMOND, PR .
PHYSICS IN MEDICINE AND BIOLOGY, 1975, 20 (04) :547-558