COMPARISON OF CARDIAC-OUTPUT MEASUREMENTS BY THERMODILUTION AND THORACIC ELECTRICAL BIOIMPEDANCE IN CRITICALLY ILL VERSUS NON-CRITICALLY ILL PATIENTS

被引:13
作者
WEISS, S [1 ]
CALLOWAY, E [1 ]
CAIRO, J [1 ]
GRANGER, W [1 ]
WINSLOW, J [1 ]
机构
[1] LOUISIANA STATE UNIV,SCH MED,DEPT MED,EMERGENCY MED SECT,NEW ORLEANS,LA
关键词
CARDIAC OUTPUT; CARDIOGRAPHY; IMPEDANCE; THERMODILUTION; CRITICAL CARE; MONITORING; PHYSIOLOGICAL METHODS;
D O I
10.1016/0735-6757(95)90045-4
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Thoracic electrical bioimpedance (TEE) has been proposed as an alternative to thermodilution (TD) for the measurement of cardiac output in settings such as the Emergency Department where invasive monitoring is not available. Validation studies comparing TEE with TD suggest a wide range of variability in the agreement between the two methods. This prospective study tests the hypothesis that this variability may be related to the severity of patient illness. Fifteen non-critically ill patients undergoing cardiac catheterization and 13 critically ill patients who underwent Swan-Ganz catheterization in the medical intensive care unit (MICU) were enrolled. Fifty-one pairs of data from the catheterization laboratory and 49 pairs of data from the MICU were obtained. The patients were graded retrospectively according to the APACHE II scoring system. The mean difference (bias) between TEE and TD results was calculated for each patient using the method suggested by Bland and Altman. A pooled t-test was performed to determine whether there was any significant difference between the APACHE II scores or cardiac output measurements obtained by TEE and TD in the two groups. APACHE II scores were 4.7 +/- 1.2 for the catheterization laboratory and 14.2 +/- 5.0 for the intensive care unit patients (P < .001). The catheterization laboratory (cath lab) group bias was 0.23 +/- 2.19, whereas the MICU bias was .002 +/- 2.33. There was no significant difference in the bias between the two groups despite significant differences in the APACHE II scores, Standard deviations of the bias were less than 15% different from each other. There is no statistically significant difference in the bias in the two groups, indicating that the systematic error is low. However, the high standard deviation suggests imprecision. The variability of bias results for the comparison of TEB and TD that is reported in the literature may not be related to the severity of the patient's illness. The results of our data indicate that the TD/TEB bias is similar across a wide range of patient conditions and severity. This would suggest that TEE would perform equally across the spectrum of patients seen in an Emergency Department. Copyright (C) 1995 by W.B. Saunders Company
引用
收藏
页码:626 / 631
页数:6
相关论文
共 41 条
  • [1] Bernstein, Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance, Crit Care Med, 14, pp. 898-901, (1986)
  • [2] Bernstein, Noninvasive cardiac output measurement, Textbook of Critical Care, pp. 159-185, (1989)
  • [3] Appel, Kram, Mackabee, Et al., Comparison of measurements of cardiac output by bioimpedance and thermodilution in severely ill surgical patients, Crit Care Med, 14, pp. 933-935, (1986)
  • [4] Sherwood, Carter, Murphy, Cardiac output by impedance cardiography: two alternative methodologies compared with thermodilution., Aviat Space Environ Med, (1991)
  • [5] Jewkes, Sear, Verhoeff, Et al., Non invasive measurement of cardiac output by thoracic electrical bioimpedance: A study of reproducibility and comparison with thermodilution, Br J Anaesth, 67, (1991)
  • [6] Ng, Walley, Tsao, Et al., Comparison and reproducibility of transthoracic bioimpedance and dual beam Doppler ultrasound measurement of cardiac function in healthy volunteers, Br J Clin Pharmacol, 32, pp. 275-282, (1991)
  • [7] Spinale, Hendrick, Crawford, Et al., Relationship between bioimpedance, thermodilution, and ventriculographic measurements in experimental congestive heart failure, Cardiovasc Res, 24, (1990)
  • [8] Huang, Stoddard, Tsueda, Et al., Stroke volume measurements by electrical bioimpedance and echocardiography in healthy volunteers, Crit Care Med, 18, pp. 1274-1278, (1990)
  • [9] Spinale, Smith, Crawford, Relationship of bioimpedance to thermodilution and echocardiographic measurements of cardiac function, Crit Care Med, 18, (1990)
  • [10] Northridge, Findlay, Wilson, Et al., Non invasive determination of cardiac output by doppler echocardiography and electrical bioimpedance, Br Heart J, 63, (1990)