DUPLEX SCANNING OF THE PERIPHERAL ARTERIES - CORRELATION OF THE PEAK VELOCITY RATIO WITH ANGIOGRAPHIC DIAMETER REDUCTION

被引:268
作者
RANKE, C [1 ]
CREUTZIG, A [1 ]
ALEXANDER, K [1 ]
机构
[1] UNIV HANOVER,SCH MED,DEPT INTERNAL MED,DIV ANGIOL,W-3000 HANNOVER,GERMANY
关键词
ULTRASONICS; PULSED DOPPLER; BLOOD FLOW VELOCITY; DUPLEX ULTRASOUND; STENOSES; QUANTIFICATION; PERIPHERAL ARTERIAL OCCLUSIVE DISEASE; ANGIOGRAPHY;
D O I
10.1016/0301-5629(92)90082-L
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The correlation of the peak systolic velocity (PSV) and the peak velocity ratio (PVR, calculated as intrastenotic PSV divided by proximally recorded PSV) with percent diameter reduction was studied in 62 patients with peripheral arterial occlusive disease. PSV values correlated well with angiographic diameter reduction (r = 0.81, n = 106 stenoses), but due to large variability the sensitivity and specificity in the detection of >50% stenoses were only 66% and 80% (for a cutoff value of 180 cm/s). The PVR showed less interindividual variability and exhibited a strong correlation with percent diameter reduction (r = 0.93, n = 106 stenoses). A 2.4 fold increase of the peak systolic velocity values with respect to the proximal site (i.e., PVR = 2.4) or more indicated a more than 50% stenosis with a sensitivity of 87% and a specificity of 94%. Figures for PVR are provided to quantitate the degree of stenoses in the 50-99% range. Calculation of PVR may normalize for patient variation and allow noninvasive quantification of lumen narrowing with high sensitivity and specificity.
引用
收藏
页码:433 / 440
页数:8
相关论文
共 17 条
  • [1] A CRITICAL-STUDY OF ULTRASOUND DOPPLER SPECTRAL-ANALYSIS FOR DETECTING CAROTID DISEASE
    BROWN, PM
    JOHNSTON, KW
    KASSAM, M
    COBBOLD, RSC
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1982, 8 (05) : 515 - &
  • [2] AN INVITRO MODEL AND ITS APPLICATION FOR THE STUDY OF CAROTID DOPPLER SPECTRAL BROADENING
    DOUVILLE, Y
    JOHNSTON, KW
    KASSAM, M
    ZUECH, P
    COBBOLD, RSC
    JARES, A
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1983, 9 (04) : 347 - 356
  • [3] DUPLEX ULTRASOUND SCANNING OF THE CAROTID ARTERIES WITH VELOCITY SPECTRUM ANALYSIS
    GARTH, KE
    CARROLL, BA
    SOMMER, FG
    OPPENHEIMER, DA
    [J]. RADIOLOGY, 1983, 147 (03) : 823 - 827
  • [4] DUPLEX CAROTID SONOGRAPHY - CRITERIA FOR STENOSIS, ACCURACY, AND PITFALLS
    JACOBS, NM
    GRANT, EG
    SCHELLINGER, D
    BYRD, MC
    RICHARDSON, JD
    COHAN, SL
    [J]. RADIOLOGY, 1985, 154 (02) : 385 - 391
  • [5] ULTRASONIC DUPLEX SCANNING IN THE DIAGNOSIS OF VASCULAR-DISEASE
    JAGER, K
    BOLLINGER, A
    SIEGENTHALER, W
    [J]. DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1986, 111 (42) : 1608 - 1613
  • [6] NONINVASIVE MAPPING OF LOWER-LIMB ARTERIAL LESIONS
    JAGER, KA
    PHILLIPS, DJ
    MARTIN, RL
    HANSON, C
    ROEDERER, GO
    LANGLOIS, YE
    RICKETTS, HJ
    STRANDNESS, DE
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (03) : 515 - 521
  • [7] ASSESSMENT OF SEVERITY OF CORONARY STENOSES USING A DOPPLER CATHETER - VALIDATION OF A METHOD BASED ON THE CONTINUITY EQUATION
    JOHNSON, EL
    YOCK, PG
    HARGRAVE, VK
    SREBRO, JP
    MANUBENS, SM
    SEITZ, W
    PORTS, TA
    [J]. CIRCULATION, 1989, 80 (03) : 625 - 635
  • [8] KEAGY BA, 1982, J CLIN ULTRASOUND, V10, P109, DOI 10.1002/jcu.1870100304
  • [9] DUPLEX SCANNING FOR DIAGNOSIS OF AORTOILIAC AND FEMOROPOPLITEAL DISEASE - A PROSPECTIVE-STUDY
    KOHLER, TR
    NANCE, DR
    CRAMER, MM
    VANDENBURGHE, N
    STRANDNESS, DE
    [J]. CIRCULATION, 1987, 76 (05) : 1074 - 1080
  • [10] ASSESSMENT OF PRESSURE-GRADIENT BY DOPPLER ULTRASOUND - EXPERIMENTAL AND CLINICAL OBSERVATIONS
    KOHLER, TR
    NICHOLLS, SC
    ZIERLER, RE
    BEACH, KW
    SCHUBART, PJ
    STRANDNESS, DE
    [J]. JOURNAL OF VASCULAR SURGERY, 1987, 6 (05) : 460 - 469