3-DIMENSIONAL POTENTIAL GRADIENT FIELDS GENERATED BY INTRACARDIAC CATHETER AND CUTANEOUS PATCH ELECTRODES

被引:88
作者
TANG, ASL
WOLF, PD
AFEWORK, Y
SMITH, WM
IDEKER, RE
机构
[1] DUKE UNIV,NSF ENGN RES CTR EMERGING CARDIOVASC TECHNOL,DURHAM,NC 27706
[2] DUKE UNIV,MED CTR,DEPT MED,DURHAM,NC 27710
[3] DUKE UNIV,MED CTR,DEPT PATHOL,DURHAM,NC 27710
关键词
DEFIBRILLATION; MAPPING; CARDIAC;
D O I
10.1161/01.CIR.85.5.1857
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Defibrillation may be improved if electrode configurations can be found that create a larger and more even voltage gradient field across the heart. This study determined the magnitude of the shock gradient fields generated by four nonthoracotomy electrode configurations for defibrillation. Methods and Results. In six dogs, a catheter was inserted containing a right ventricular apical electrode (V) and a right atrial electrode (A). A cutaneous patch electrode (P) was placed on the left lateral thorax. Shock potentials were recorded simultaneously from 128 electrodes in the left ventricular and right ventricular subepicardium and subendocardium, ventricular spetum, and atria. With the chest closed, 50-mA shocks were given during diastole via the following lead configurations: V --> A (V, cathode; A, anode); V --> P; V --> A + P; and V + A --> P. Potential gradients were calculated at the subepicardium and subendocardium in millivolts per centimeter per volt of shock. In most dogs, the V --> A + P configuration produced higher gradients throughout the ventricles than did V --> A, V --> P, or V + A --> P. The maximum potential gradient was smaller for the V + A --> P configuration than for V --> A, V --> P, or V --> A + P. The gradient fields for the configurations with the catheter alone or combined with P were uneven. Conclusions. It is possible to estimate shock gradient fields in three dimensions. Of the four configurations tested, V --> A + P produced the highest gradients and V + A --> P produced the lowest high gradient. The gradient fields were uneven throughout the ventricles.
引用
收藏
页码:1857 / 1864
页数:8
相关论文
共 32 条
  • [1] BACH S M JR, 1989, Journal of the American College of Cardiology, V13, p65A
  • [2] THE POTENTIAL GRADIENT FIELD CREATED BY EPICARDIAL DEFIBRILLATION ELECTRODES IN DOGS
    CHEN, PS
    WOLF, PD
    CLAYDON, FJ
    DIXON, EG
    VIDAILLET, HJ
    DANIELEY, ND
    PILKINGTON, TC
    IDEKER, RE
    [J]. CIRCULATION, 1986, 74 (03) : 626 - 636
  • [3] COMPARISON OF THE DEFIBRILLATION THRESHOLD AND THE UPPER LIMIT OF VENTRICULAR VULNERABILITY
    CHEN, PS
    SHIBATA, N
    DIXON, EG
    MARTIN, RO
    IDEKER, RE
    [J]. CIRCULATION, 1986, 73 (05) : 1022 - 1028
  • [4] CLAYDON FJ, 1987, THESIS DUKE U DURHAM
  • [5] CLINICAL-EXPERIENCE, COMPLICATIONS, AND SURVIVAL IN 70 PATIENTS WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    ECHT, DS
    ARMSTRONG, K
    SCHMIDT, P
    OYER, PE
    STINSON, EB
    WINKLE, RA
    [J]. CIRCULATION, 1985, 71 (02) : 289 - 296
  • [6] ENGLISH TAH, 1986, ROB SMITHS OPERATIVE, P17
  • [7] Fabiato A, 1967, Arch Mal Coeur Vaiss, V60, P527
  • [8] FUNDAMENTAL CRITERIA UNDERLYING THE EFFICACY AND SAFETY OF DEFIBRILLATING CURRENT WAVEFORMS
    GEDDES, LA
    NIEBAUER, MJ
    BABBS, CF
    BOURLAND, JD
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1985, 23 (02) : 122 - 130
  • [9] DETERMINANTS OF INTRACARDIAC CURRENT IN DEFIBRILLATION - EXPERIMENTAL STUDIES IN DOGS
    HOYT, R
    GRAYZEL, J
    KERBER, RE
    [J]. CIRCULATION, 1981, 64 (04) : 818 - 823
  • [10] IDEKER RE, 1991, CARDIAC PACING ELECT, P713