HEPATIC MR-IMAGING WITH FERUMOXIDES - A MULTICENTER CLINICAL-TRIAL OF THE SAFETY AND EFFICACY IN THE DETECTION OF FOCAL HEPATIC-LESIONS

被引:229
作者
ROS, PR
FREENY, PC
HARMS, SE
SELTZER, SE
DAVIS, PL
CHAN, TW
STILLMAN, AE
MUROFF, LR
RUNGE, VM
NISSENBAUM, MA
JACOBS, PM
机构
[1] ARMED FORCES INST PATHOL,DEPT RADIOL PATHOL,WASHINGTON,DC 20306
[2] WASHINGTON UNIV,DEPT RADIOL,SEATTLE,WA
[3] BAYLOR UNIV,MED CTR,DEPT RADIOL,DALLAS,TX
[4] BRIGHAM & WOMENS HOSP,DEPT RADIOL,BOSTON,MA 02115
[5] UNIV PITTSBURGH,MED CTR,PITTSBURGH,PA
[6] UNIV CHICAGO,CHICAGO,IL
[7] UNIV MINNESOTA,DEPT RADIOL,MINNEAPOLIS,MN
[8] UNIV COMMUNITY HOSP,TAMPA,FL
[9] UNIV KENTUCKY,LEXINGTON,KY
[10] LONG BEACH MEM HOSP MED CTR,MEM MAGNET RESONANCE INST,LONG BEACH,CA
[11] ADV MAGNET INC,CAMBRIDGE,MA 02138
关键词
CONTRAST MEDIA; EFFECTS; LIVER NEOPLASMS; MR; MAGNETIC RESONANCE (MR); CONTRAST ENHANCEMENT;
D O I
10.1148/radiology.196.2.7617864
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the safety and diagnostic efficacy of intravenous ferumoxides, a superparamagnetic iron oxide, for depiction of focal hepatic lesions on magnetic resonance (MR) images. MATERIALS AND METHODS: This open-label study included 208 patients with known or suspected focal hepatic lesions. MR images were obtained before and 45 minutes to 4 hours after intravenous infusion of ferumoxides (10 mu mol/kg). The effect of ferumoxides on signal intensity of the liver was assessed with quantitative analysis. Safety was evaluated with patient monitoring and laboratory measurements. RESULTS: Mean lesion-to-liver contrast-to-noise ratio on T2-weighted images was 9.1 on unenhanced images and 12.7 on enhanced images. Signal intensity of normal liver on enhanced images decreased to 37% of that on unenhanced images. In blinded image evaluations, additional lesions were identified on 27% of enhanced images. No serious adverse events occurred. CONCLUSION: Ferumoxides is a safe and efficacious contrast agent for the detection of focal liver lesions on T2-weighted images.
引用
收藏
页码:481 / 488
页数:8
相关论文
共 19 条
[1]  
BRUEL JM, 1993, RADIOLOGY, V189, P273
[2]  
DUDA SH, 1994, JMRI-J MAGN RESON IM, V4, P390
[3]   IRON-OXIDE ENHANCED MR-IMAGING OF THE LIVER AND SPLEEN - REVIEW OF THE 1ST-5 YEARS [J].
FERRUCCI, JT ;
STARK, DD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (05) :943-950
[4]   DETECTION OF HEPATIC METASTASES - COMPARISON OF CONTRAST-ENHANCED CT, UNENHANCED MR IMAGING, AND IRON-OXIDE ENHANCED MR IMAGING [J].
FRETZ, CJ ;
STARK, DD ;
METZ, CE ;
ELIZONDO, G ;
WEISSLEDER, R ;
SHEN, JH ;
WITTENBERG, J ;
SIMEONE, J ;
FERRUCCI, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (04) :763-770
[5]   SUPERPARAMAGNETIC IRON-OXIDE PARTICLES - REPLY [J].
GORE, JC ;
MAJUMDAR, S .
RADIOLOGY, 1988, 169 (03) :657-658
[6]   CLINICAL-APPLICATION OF SUPERPARAMAGNETIC IRON-OXIDE TO MR IMAGING OF TISSUE PERFUSION IN VASCULAR LIVER-TUMORS [J].
HAHN, PF ;
STARK, DD ;
WEISSLEDER, R ;
ELIZONDO, G ;
SAINI, S ;
FERRUCCI, JT .
RADIOLOGY, 1990, 174 (02) :361-366
[7]   DETECTION OF FOCAL HEPATIC MASSES - PROSPECTIVE EVALUATION WITH CT, DELAYED CT, CT DURING ARTERIAL PORTOGRAPHY, AND MR IMAGING [J].
HEIKEN, JP ;
WEYMAN, PJ ;
LEE, JKT ;
BALFE, DM ;
PICUS, D ;
BRUNT, EM ;
FLYE, MW .
RADIOLOGY, 1989, 171 (01) :47-51
[8]   THE EFFECTS OF IRON-OXIDES ON PROTON RELAXIVITY [J].
JOSEPHSON, L ;
LEWIS, J ;
JACOBS, P ;
HAHN, PF ;
STARK, DD .
MAGNETIC RESONANCE IMAGING, 1988, 6 (06) :647-653
[9]   PHARMACOKINETICS OF SUPERPARAMAGNETIC IRON-OXIDE MR CONTRAST AGENTS IN THE RAT [J].
MAJUMDAR, S ;
ZOGHBI, SS ;
GORE, JC .
INVESTIGATIVE RADIOLOGY, 1990, 25 (07) :771-777
[10]   DETECTION OF LIVER METASTASES WITH SUPERPARAMAGNETIC IRON-OXIDE IN 15 PATIENTS - RESULTS OF MR IMAGING AT 1.5-T [J].
MARCHAL, G ;
VANHECKE, P ;
DEMAEREL, P ;
DECROP, E ;
KENNIS, C ;
BAERT, AL ;
VANDERSCHUEREN, E .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (04) :771-775