VALIDATION-STUDY OF SKULL 3-DIMENSIONAL COMPUTERIZED-TOMOGRAPHY MEASUREMENTS

被引:92
作者
HILDEBOLT, CF
VANNIER, MW
KNAPP, RH
机构
[1] Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Missouri
关键词
3‐D CT; Anthropometric; Craniometry; CT;
D O I
10.1002/ajpa.1330820307
中图分类号
Q98 [人类学];
学科分类号
030303 ;
摘要
Recent advances in imaging have led to high‐resolution computerized tomography (CT) scanning with exquisitely detailed slice images of the skull and three‐dimensional (3‐D) surface reconstructions using computer software. It is possible to use CT scans to acquire morphologic information about the skull in a convenient digital form and to derive 3‐D measurements from surface reconstruction images. Unfortunately, no effort has been made to date to test the validity of these measurements on laboratory specimens, and no compelling evidence is available from phantom studies to indicate the nature and magnitude of the errors inherent in the measurement technique. We have performed a pilot study to quantify the morphology of the skull based on surface features that can be found in CT scans and 3‐D reconstructions. Comparative measurements were obtained from five skulls (two normal and three with dysmorphology) with calipers and a 3‐D electromagnetic digitizer. These measurements were statistically compared with those based on original CT scan slices and reformatted 3‐D images. It is concluded that 3D‐CT measurements techniques are superior to those in which measurements are obtained directly from the original CT slices; 3‐D CT methods, however, must be significantly improved before measurements based on these techniques can be used in studies that require a high degree of precision. The results are used to indicate the most fruitful areas of future study. Copyright © 1990 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:283 / 294
页数:12
相关论文
共 30 条
  • [1] BASS WM, 1981, HUMAN OSTEOLOGY LABO
  • [2] Broadbent B. H. S., 1975, BOLTON STANDARDS DEN
  • [3] Brothwell D.R., 1981, DIGGING BONES EXCAVA, Vthird
  • [4] CHEVERUD JM, 1986, SYST ZOOL, V35, P109
  • [5] NONINVASIVE 3-DIMENSIONAL COMPUTER IMAGING OF MATRIX-FILLED FOSSIL SKULLS BY HIGH-RESOLUTION COMPUTED-TOMOGRAPHY
    CONROY, GC
    VANNIER, MW
    [J]. SCIENCE, 1984, 226 (4673) : 456 - 458
  • [6] DENTAL DEVELOPMENT OF THE TAUNG SKULL FROM COMPUTERIZED-TOMOGRAPHY
    CONROY, GC
    VANNIER, MW
    [J]. NATURE, 1987, 329 (6140) : 625 - 627
  • [7] DYE DM, 1984, 8TH P C COMP RAD, P233
  • [8] GAYOU DE, 1984, 8TH P ANN C COMP RAD, P269
  • [9] Geist D., 1988, Proceedings of the SPIE - The International Society for Optical Engineering, V914, P1299, DOI 10.1117/12.968780
  • [10] HANSON KM, 1985, SPIE, V535, P70