FABRICATION AND CHARACTERIZATION OF GOLD PLATED EDGES ON THIN SUBSTRATES FOR MEASUREMENT OF E-BEAM DIAMETER

被引:5
作者
GENTILI, M
GRELLA, L
LUCIANI, L
BACIOCCHI, M
DIFABRIZIO, E
WALLMAN, BA
机构
[1] Instituto di Elettronica dello Stato Solido-CNR, I-00156 Roma
[2] Leica Cambridge, CB1 3QH Cambridge, Clifton Road
关键词
ELECTRON BEAM DIAMETER MEASUREMENT; MONTE-CARLO SIMULATION; ELECTRON SCATTERING; ELECTROPLATING;
D O I
10.1016/0167-9317(91)90004-W
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Gold plated edges were fabricated on various substrates and were used as targets for precise electron beam diameter measurement and for system calibration in a commercial Cambridge Instruments e-beam lithography machine. Use of 4-mu-m square gold plated marker (0.85-mu-m thick), fabricated on 2-mu-m thick silicon nitride membrane, was found to enhance significantly the marker-to-substrate signal ratio, in comparison to commonly used lifted-off marker, and thus has improved the reliability of beam diameter measurement accuracy at low beam current for a 40 kV beam voltage. In a statistical sampling of about 2000 measurements, an accuracy of 5 nm (1 sigma value) has been obtained for 38 nm beam diameter by using this gold plated edge on silicon nitride membrane. Further, a Monte Carlo program, which models the effects of electron scattering taking place in target and substrate was used to increase the understanding of the experimental results. Simulated contrast behaviour was found to agree well with the experimental data for all three types of marker used in this study. Finally, the influence of the geometrical shape of the marker edge on beam diameter measurement was studied. By using an appropriate analytical function it was possible to take into account the effect of not perfectly vertical edge on small beam diameter measurements.
引用
收藏
页码:183 / 196
页数:14
相关论文
共 8 条
[1]  
Rosenfield, Bucchignano, Rishton, Kern, Kettel, Molzen, Hohn, Viswanathan, Warlaumont, Submicron electron beam lithography using a beam size comparable to the linewidth control tolerance, Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures, 5, 1, (1987)
[2]  
Rishton, Beaumont, Wilkinson, Measurements of the profile of finely focused electron beams in a scanning electron microscope, J. Phys. E: Sci. Instrum., 17, (1984)
[3]  
Penberth, Wallman, Low profile collector system, J. Vac. Sci. Technol., 16, 6, (1979)
[4]  
Chisholm, Spot-size measurement in an electron-beam pattern generator, Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures, 6, 6, (1988)
[5]  
Brewer, Electron Beam Technology in Microelectronic Fabrication, pp. 230-232, (1980)
[6]  
Van Leeuwen, van Vucht, Romijn, van der Drift, Tungsten calibration mark for electron beam pattern generators, Microelectron. Eng., 9, (1989)
[7]  
Jones, Dix, Electron beam lithography in telecommunication device fabrication, Br. Telecom. Technol. J., 7, 1, (1989)
[8]  
James, CERN computing and data processing school, (1972)