ADAPTATION OF ONLINE REACTIONS DEVELOPED FOR USE WITH FLOW-INJECTION WITH AMPEROMETRIC DETECTION FOR USE IN DISPOSABLE SENSOR DEVICES - REDUCTIVE DETERMINATION OF PHOSPHATE AS PREFORMED 12-MOLYBDOPHOSPHATE IN A CAPILLARY-FILL DEVICE

被引:17
作者
FOGG, AG [1 ]
SCULLION, SP [1 ]
EDMONDS, TE [1 ]
BIRCH, BJ [1 ]
机构
[1] UNILEVER RES LABS,SHARNBROOK MK44 1LQ,BEDS,ENGLAND
关键词
Amperometric detection; Capillary-fill device; Disposable sensor; Flow injection; Phosphate determination;
D O I
10.1039/an9901501277
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Preliminary experiments have been carried out to show that on-line reactions developed for use with flow injection can be adapted for use in capillary-fill devices. The reversibility of the oxidation of a 1 times; 10 -3 M solution of potassium hexacyanoferrate(ll) in 1 M HCl solution at a screen-printed carbon electrode in a capillary-fill device (CFD) incorporating a screen-printed silver reference electrode was found to be only slightly less than at a smoothly operating glassy carbon electrode (GCE) [E pa - Epc = 95 mV (CFD), 65 mV (GCE)]. For the determination of phosphate as 12-molybdophosphate by reduction at a screen-printed carbon electrode in a CFD, a device with a screen-printed unchloridised silver reference/counter electrode was preferred to a chloridised silver electrode. A stable measurement potential was obtained when the measured solution was made 0.1 M in potassium chloride. The presence of potassium ion was found to affect markedly the linear sweep voltammograms obtained for the reduction of 12-molybdophosphate particularly at a GCE but also to a lesser extent at a screen-printed carbon electrode; this effect was controlled in further work with the CFD by the inclusion of potassium chloride in the measured solution. A rectilinear response was obtained for 5 × 10-6 M (the detection limit) -2 × 10-3 M pre-formed 12-molybdophosphate solutions at an applied potential of 0.16 V. The acidity required to carry out the reaction of phosphate can be provided by the addition of potassium hydrogen sulphate. It should be possible, therefore, to produce a satisfactory CFD for the determination of phosphate by screen-printing a mixture of sodium molybdate, potassium hydrogen sulphate and potassium chloride on to the glass face opposite to the screen-printed electrodes.
引用
收藏
页码:1277 / 1281
页数:5
相关论文
共 22 条
[1]  
BIRCH BJ, 1987, Patent No. 3105274
[2]  
BIRCH BJ, 1987, Patent No. 873065130
[3]  
BOLTZ DF, 1949, ANAL CHEM, V5, P563
[4]   OXIDATIVE FLOW-INJECTION AMPEROMETRIC DETERMINATION OF NITRITE AT AN ELECTROCHEMICALLY PRE-TREATED GLASSY-CARBON ELECTRODE [J].
CHAMSI, AY ;
FOGG, AG .
ANALYST, 1988, 113 (11) :1723-1727
[5]   IODIMETRIC AND BROMIMETRIC FLOW-INJECTION AMPEROMETRIC METHODS OF DETERMINING SULFITE IN WHICH IODINE OR BROMINE IS MONITORED AT A GLASSY-CARBON ELECTRODE [J].
FOGG, AG ;
GUTA, CW ;
CHAMSI, AY .
ANALYST, 1987, 112 (03) :253-258
[6]   SHAPES OF NORMAL AND REVERSE FLOW-INJECTION SIGNALS - ONLINE FORMATION OF IODINE FROM IODATE, IODIDE AND HYDROGEN-ION WITH DETECTION BY VISIBLE SPECTROPHOTOMETRY [J].
FOGG, AG ;
WANG, XW ;
TYSON, JF .
ANALYST, 1989, 114 (09) :1119-1123
[7]   AMPEROMETRIC FLOW-INJECTION DETERMINATION OF ETHYLENEDIAMINETETRAACETIC ACID (EDTA) AT AN ELECTROCHEMICALLY PRE-TREATED GLASSY-CARBON ELECTRODE [J].
FOGG, AG ;
FERNANDEZARCINIEGA, MA ;
ALONSO, RM .
ANALYST, 1985, 110 (10) :1201-1204
[8]   OXIDATIVE AMPEROMETRIC FLOW-INJECTION DETERMINATION OF SULFITE AT AN ELECTROCHEMICALLY PRE-TREATED GLASSY-CARBON ELECTRODE [J].
FOGG, AG ;
FERNANDEZARCINIEGA, MA ;
ALONSO, RM .
ANALYST, 1985, 110 (07) :851-853
[9]   OXIDATIVE AMPEROMETRIC FLOW-INJECTION DETERMINATION OF CYANIDE AT AN ELECTROCHEMICALLY PRETREATED GLASSY-CARBON ELECTRODE [J].
FOGG, AG ;
ALONSO, RM .
ANALYST, 1987, 112 (07) :1071-1072
[10]   FLOW-INJECTION VOLTAMMETRIC DETERMINATION OF NITRITE BY REDUCTION AT A GLASSY-CARBON ELECTRODE IN ACIDIC BROMIDE OR CHLORIDE MEDIA [J].
FOGG, AG ;
BSEBSU, NK ;
ABDALLA, MA .
ANALYST, 1982, 107 (1278) :1040-1046