IMPLEMENTATION OF ECHO-PLANAR IMAGING ON AN UNMODIFIED SPECTROMETER AT 2.1-TESLA FOR FUNCTIONAL IMAGING

被引:6
作者
BLAMIRE, AM
SHULMAN, RG
机构
[1] Department of Molecular Biophysics and Biochemistry, Yale University, New Haven
关键词
ECHO-PLANAR IMAGING; SHIMMING; OVERSAMPLING; POINT SPREAD FUNCTION; FUNCTIONAL IMAGING;
D O I
10.1016/0730-725X(94)92462-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The high speed magnetic resonance imaging technique of Echo-Planar imaging (EPI) has been developing since 1977 using specialized imaging systems. Recent experiments in functional magnetic resonance imaging (FMRI) using EPI on specialized MR systems have generated increased interest in the EPI sequence. Presented here is an implementation of the EPI sequence on a large bore, human scale spectrometer using widely available standard hardware. Existing EPI methods and concepts were amalgamated to obtain images without hardware modifications, Spatial distortion of Echo-Planar images by internal field gradients within the brain were minimized by active shimming on each subject. Nonlinear sampling artifacts caused by nonideal gradient switching were addressed by oversampling the signal and simple extraction of data points corresponding to the ideal sampling pattern. Multislice Echo-Planar images with functional contrast have been obtained at 6 x 3 mm resolution using these methods.
引用
收藏
页码:669 / 673
页数:5
相关论文
共 25 条
[1]  
Mansfield, Multi-Planar image formation using NMR spin echoes, J. Phys. C., 10, pp. L55-L58, (1977)
[2]  
Ordidge, Coxon, Howseman, Chapman, Turner, Stehling, Mansfield, Snapshot head imaging at 0.5T using the Echo-Planar technique, Magn. Reson. Med., 8, pp. 110-115, (1988)
[3]  
Stehling, Charnley, Blamire, Ordidge, Coxon, Gibbs, Hardcastle, Mansfield, Ultrafast magnetic resonance scanning of the liver with Echo-Planar imaging, Br. J. Radiol., 63, pp. 430-437, (1990)
[4]  
Mansfield, Stehling, Ordidge, Coxon, Chapman, Blamire, Gibbs, Johnson, Symonds, Worthington, Coupland, Echo-Planar imaging of the human fetus in utero at 0.5T, Br. J. Radiol., 63, pp. 833-841, (1990)
[5]  
Firmin, Klipstein, Hounsfield, Paley, Longmore, Echo-Planar high-resolution flow velocity mapping, Magn. Reson. Med., 12, pp. 316-327, (1989)
[6]  
Cohen, Weisskoff, Ultra-Fast imaging, Magn. Reson. Imag., 9, pp. 1-37, (1991)
[7]  
Pykett, Rzedzian, Instant images of the body by magnetic resonance, Magn. Reson. Med., 5, pp. 563-571, (1987)
[8]  
Blackband, Chatham, O'Dell, Day, Echo-Planar imaging of isolated perfused rat hearts at 4.7T: A comparison of Langendorff and working heart preparations, Magn. Reson. Med., 15, pp. 240-245, (1990)
[9]  
Turner, Le Bihan, Chesnick, Echo-Planar imaging of diffusion and perfusion, Magn. Reson. Med., 19, pp. 247-253, (1991)
[10]  
Belliveau, Kennedy, McKinstry, Buchbinder, Cohen, Vevea, Brady, Rosen, Functional mapping of the human visual cortex by magnetic resonance imaging, Science, 254, pp. 716-719, (1991)