CARDIAC-FUNCTION DURING ORTHOTOPIC LIVER-TRANSPLANTATION WITH VENOVENOUS BYPASS

被引:18
作者
CHEEMA, SPS [1 ]
HUGHES, A [1 ]
WEBSTER, NR [1 ]
BELLAMY, MC [1 ]
机构
[1] UNIV ABERDEEN,ABERDEEN ROYAL INFIRM,DEPT ANAESTHESIA,ABERDEEN,SCOTLAND
关键词
ANESTHESIA; LIVER TRANSPLANTATION; HEART; CARDIAC OUTPUT;
D O I
10.1111/j.1365-2044.1995.tb06138.x
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
We have studied the effect of varying the flow of a venovenous bypass system during orthotopic liver transplantation. During these manipulations, central venous (n = 9) or pulmonary artery occlusion (n = 9) pressures were kept constant. There was no change in right ventricular systolic or diastolic function in either group, suggesting that any conformational change of the ventricle during bypass is not of functional significance. The extrapolated volume loading required to compensate for the absence of bypass is of the order of 3000 ml.
引用
收藏
页码:776 / 778
页数:3
相关论文
共 7 条
[1]
DEWOLF AM, 1993, ANESTH ANALG, V76, P562
[2]
ELLIS JE, 1989, ANESTH ANALG, V68, P777
[3]
GABRIEL A, 1993, TRANSPLANT P, V25, P1811
[4]
KINDSCHER J, 1993, TRANSPLANT P, V25, P1824
[5]
PAULSEN AW, 1989, ANESTH ANALG, V68, P489
[6]
ADVANTAGES OF VENOUS BYPASS DURING ORTHOTOPIC TRANSPLANTATION OF THE LIVER [J].
SHAW, BW ;
MARTIN, DJ ;
MARQUEZ, JM ;
KANG, YG ;
BUGBEE, AC ;
IWATSUKI, S ;
GRIFFITH, BP ;
HARDESTY, RL ;
BAHNSON, HT ;
STARZL, TE .
SEMINARS IN LIVER DISEASE, 1985, 5 (04) :344-348
[7]
BLOOD AND PLASMA VOLUMES DETERMINED BY CARBON-MONOXIDE GAS, TC-99M-LABELED ERYTHROCYTES, I-125 ALBUMIN AND THE T-1824 TECHNIQUE [J].
THOMSEN, JK ;
FOGHANDERSEN, N ;
BULOW, K ;
DEVANTIER, A .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1991, 51 (02) :185-190