ON ESTIMATING THE AMPLITUDE OF HARMONIC VIBRATION FROM THE DOPPLER SPECTRUM OF REFLECTED SIGNALS

被引:54
作者
HUANG, SR
LERNER, RM
PARKER, KJ
机构
[1] UNIV ROCHESTER,DEPT FOOD TECHNOL,ROCHESTER,NY 14642
[2] UNIV ROCHESTER,ROCHESTER CTR BIOMED ULTRASOUND,ROCHESTER,NY 14627
关键词
D O I
10.1121/1.399673
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The Doppler spectrum of echoes from a sinusoidally vibrating scatterer has discrete spectral lines weighted by Bessel functions of the first kind. Because the signal and spectrum are complicated functions of the vibration amplitude, a number of different approaches have been tried in the past to estimate the vibration amplitude, given a received signal. Here, a new and simple relationship between the spread (or variance) of the Doppler spectrum and the vibration amplitude is derived. A method of estimating the vibration amplitude is proposed based on this relation and a noise compensation procedure is also demonstrated. The performance of the estimators is studied through simulations. High accuracy is predicted under proper sampling conditions even when the signal-to-noise ratio is poor. Slight deviations from single-frequency oscillation, as would be caused by nonlinear or nonideal medium or source effects, are found to have little contribution to the total estimation error. © 1990, Acoustical Society of America. All rights reserved.
引用
收藏
页码:2702 / 2712
页数:11
相关论文
共 14 条
[1]  
CARLSON AB, 1986, COMMUNICATIONS SYSTE, P221
[2]   ACOUSTICAL DOPPLER-EFFECT ANALYSIS - IS IT A VALID METHOD [J].
CENSOR, D .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1988, 83 (04) :1223-1230
[3]   AUTOMATED NONINVASIVE MOTION MEASUREMENT OF AUDITORY ORGANS IN FISH USING ULTRASOUND [J].
COX, M ;
ROGERS, PH .
JOURNAL OF VIBRATION ACOUSTICS STRESS AND RELIABILITY IN DESIGN-TRANSACTIONS OF THE ASME, 1987, 109 (01) :55-59
[4]   REPRESENTATIONS OF RAPIDLY OSCILLATING STRUCTURES ON THE DOPPLER DISPLAY [J].
HOLEN, J ;
WAAG, RC ;
GRAMIAK, R .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (02) :267-272
[5]  
JARZYNSKI J, 1988, SPIE, V925, P250
[6]   REAL-TIME TWO-DIMENSIONAL BLOOD-FLOW IMAGING USING AN AUTO-CORRELATION TECHNIQUE [J].
KASAI, C ;
NAMEKAWA, K ;
KOYANO, A ;
OMOTO, R .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1985, 32 (03) :458-464
[8]  
Lerner R. M., 1988, Acoustical Imaging. Vol.19. Proceedings of the 16th International Symposium, P317
[9]   SONOELASTICITY IMAGES DERIVED FROM ULTRASOUND SIGNALS IN MECHANICALLY VIBRATED TISSUES [J].
LERNER, RM ;
HUANG, SR ;
PARKER, KJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (03) :231-239
[10]   CENSORS ACOUSTICAL DOPPLER-EFFECT ANALYSIS - IS IT A VALID METHOD [J].
PIQUETTE, JC ;
VANBUREN, AL ;
ROGERS, PH .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1988, 83 (04) :1681-1682