THE MICRO-TRAP - AN ALTERNATIVE TO CRYOFOCUSING IN CAPILLARY GAS-CHROMATOGRAPHY

被引:27
作者
FRANK, W [1 ]
FRANK, H [1 ]
机构
[1] UNIV TUBINGEN,INST TOXIKOL,WILHELMSTR 56,W-7400 TUBINGEN 1,GERMANY
关键词
Airborne halocarbons; Capillary columns; Gas chromatography; Micro-trap; Trace analysis;
D O I
10.1007/BF02261224
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
For routine analyses involving numerous samples or for field operation of on-site instruments, cryogenic traps are inconvenient: their operation is timeconsuming and automation is technically demanding. complete trapping and efficient band-focussing may be achieved at ambient temperature with micro-traps packed with suitable sorbents. Two approaches have been evaluated: if the boiling points of the analytes are within a range of about 100°C, a single-sorbent trap and direct coupling to the column are recommended; for samples containing components wih widely different volatilities, a trap composed of two or more segments with complementary affinties and coupling to the chromatographic column under carrier-gas flow-reversion is preferable. The procedure has been evaluated for airborne C1 and C2-halocarbons; it is also applicable to trace analysis of other volatile organic air pollutants. © 1990 Friedr. Vieweg & Sohn Verlagsgesellschaft mbH.
引用
收藏
页码:571 / 574
页数:4
相关论文
共 18 条
[1]   2-DIMENSIONAL GAS-CHROMATOGRAPHY FOR DETERMINATION OF VOLATILE COMPOUNDS IN AMBIENT AIR [J].
BERG, S ;
JONSSON, A .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1984, 7 (12) :687-695
[2]  
Deans D.R., 1968, CHROMATOGRAPHIA, V1, P18, DOI DOI 10.1007/BF02259005
[3]   OPTIMIZATION OF THE GAS-CHROMATOGRAPHIC DETERMINATION OF AIRBORNE HALOCARBONS [J].
FRANK, H ;
FRANK, W .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 332 (02) :115-121
[4]   HOW EFFICIENT ARE CAPILLARY COLD TRAPS [J].
GRAYDON, JW ;
GROB, K .
JOURNAL OF CHROMATOGRAPHY, 1983, 254 (JAN) :265-269
[5]   DETERMINATION OF HIGHLY VOLATILE ORGANIC CONTAMINANTS IN WATER BY THE CLOSED-LOOP GASEOUS STRIPPING TECHNIQUE FOLLOWED BY THERMAL-DESORPTION OF THE ACTIVATED CARBON FILTERS [J].
GRAYDON, JW ;
GROB, K ;
ZUERCHER, F ;
GIGER, W .
JOURNAL OF CHROMATOGRAPHY, 1984, 285 (02) :307-318
[6]   CAPILLARY COLUMNS WITH VERY THICK COATINGS [J].
GROB, K ;
GROB, G .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1983, 6 (03) :133-139
[7]  
HURREL RA, 1987, 8TH P INT S CAP CHRO, V1, P445
[8]   ANALYSIS OF VOLATILE ORGANIC-COMPOUNDS IN POLYMERS BY DYNAMIC HEADSPACE AND GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
JACOBSSON, S .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1984, 7 (04) :185-190
[9]  
KELKER H, 1979, FRESENIUS Z ANAT CHE, V297, P357
[10]  
MULLER S, 1990, J HIGH RES CHROMATOG, V13, P34