AUTOMATED VOLUME DETERMINATION OF THE LIVER AND SPLEEN FROM TC-99M COLLOID SPECT IMAGING - QUANTIFICATION OF THE LIVER FUNCTIONAL AND NONFUNCTIONAL TISSUE IN DISEASE

被引:9
作者
KAVANAGH, GJ
KAVANAGH, JT
KAVANAGH, PBK
IRWIN, LE
PERKINS, AC
SWANSON, LA
机构
[1] UNIV NOTTINGHAM,DEPT PHYSIOL & PHARMACOL,NOTTINGHAM NG7 2RD,ENGLAND
[2] MIT,DEPT BIOELECT ENGN,CAMBRIDGE,MA 02139
[3] UNIV SO CALIF,DEPT ONCOL,LOS ANGELES,CA 90089
[4] UNIV NOTTINGHAM,DEPT MED PHYS,NOTTINGHAM NG7 2RD,ENGLAND
关键词
D O I
10.1097/00003072-199007000-00009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An automated volume determination program using SPECT imaging with Tc-99m has been validated by both phantom and patient studies. Its use for monitoring change of function of the liver and change in tumor mass during different therapy regimes has been assessed. The technique is not restricted to the estimation of the hepatic functioning tissues; it therefore has many potential clinical implementations for volume determination in other organs.
引用
收藏
页码:495 / 500
页数:6
相关论文
共 11 条
[1]   COMPUTED-TOMOGRAPHY ASSISTED VOLUMETRIC-ANALYSIS OF PRIMARY LIVER-TUMOR AS A MEASURE OF RESPONSE TO THERAPY [J].
ETTINGER, DS ;
LEICHNER, PK ;
SIEGELMAN, SS ;
FISHMAN, EK ;
KLEIN, JL ;
ORDER, SE .
AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 1985, 8 (05) :413-418
[2]   MEASUREMENT OF LIVER AND SPLEEN VOLUME BY COMPUTED-TOMOGRAPHY - ASSESSMENT OF REPRODUCIBILITY AND CHANGES FOUND FOLLOWING A SELECTIVE DISTAL SPLENORENAL SHUNT [J].
HENDERSON, JM ;
HEYMSFIELD, SB ;
HOROWITZ, J ;
KUTNER, MH .
RADIOLOGY, 1981, 141 (02) :525-527
[3]   ACCURATE MEASUREMENT OF LIVER, KIDNEY, AND SPLEEN VOLUME AND MASS BY COMPUTERIZED AXIAL-TOMOGRAPHY [J].
HEYMSFIELD, SB ;
FULENWIDER, T ;
NORDLINGER, B ;
BARLOW, R ;
SONES, P ;
KUTNER, M .
ANNALS OF INTERNAL MEDICINE, 1979, 90 (02) :185-187
[4]   ORGAN VOLUME DETERMINATION BY CT SCANNING - REDUCTION OF RESPIRATION-INDUCED ERRORS BY FEEDBACK MONITORING [J].
JONES, KR ;
ROBINSON, PJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (01) :167-171
[5]   ULTRASONIC DETERMINATION OF LIVER AND SPLEEN VOLUMES [J].
KARDEL, T ;
HOLM, HH ;
RASMUSSEN, SN ;
MORTENSEN, T .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1971, 27 (02) :123-+
[6]  
LUANG NW, 1986, J HEPATOL, V2, P157
[7]   LIVER VOLUME MEASUREMENTS AND 3-DIMENSIONAL DISPLAY FROM MR IMAGES [J].
MCNEAL, GR ;
MAYNARD, WH ;
BRANCH, RA ;
POWERS, TA ;
ARNS, PA ;
GUNTER, K ;
FITZPATRICK, JM ;
PARTAIN, CL .
RADIOLOGY, 1988, 169 (03) :851-854
[8]  
MUT F, 1988, J NUCL MED, V29, P1768
[9]   LIVER VOLUME DETERMINATION BY ULTRASONIC SCANNING [J].
RASMUSSEN, SN .
BRITISH JOURNAL OF RADIOLOGY, 1972, 45 (536) :579-+
[10]  
SATO S, 1987, Radioisotopes, V36, P265, DOI 10.3769/radioisotopes.36.6_265