FIXATION WITH BIOABSORBABLE SCREWS FOR THE TREATMENT OF FRACTURES OF THE ANKLE

被引:192
作者
BUCHOLZ, RW
HENRY, S
HENLEY, MB
机构
[1] PARKLAND MEM HOSP & AFFILIATED INST,DALLAS,TX 75235
[2] UNIV WASHINGTON,HARBORVIEW MED CTR,SEATTLE,WA 98104
[3] COLUMBIA UNIV LOUISVILLE HOSP,LOUISVILLE,KY
[4] UNIV LOUISVILLE,SCH MED,DEPT ORTHOPAED SURG,LOUISVILLE,KY 40201
[5] UNIV WASHINGTON,SCH MED,DEPT ORTHOPAED SURG,SEATTLE,WA 98195
关键词
D O I
10.2106/00004623-199403000-00001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
One hundred and fifty-five patients who had a closed, displaced medial malleolar, bimalleolar, or trimalleolar fracture of the ankle were managed with medial malleolar fixation with use of either 4.0-millimeter orientruded polylactide screws (eighty-three patients, study group) or 4.0-millimeter stainless-steel screws (seventy-two patients, control group). All lateral malleolar fractures were stabilized with standard metallic implants. At an average of thirty-seven months (range, twenty-one to fifty-nine months), the radiographic and functional results in the two groups were equivalent. Differences between the two groups with regard to the rates of operative and postoperative complications were not statistically significant. Late spontaneous drainage of the hydrolyzed polylactide was not noted in any patient in the study group. The prevalence of late tenderness over the medial malleolar implant was lower in the patients in whom the fracture had been stabilized with polylactide screws. We conclude that polylactide screws are a safe and effective alternative to stainless-steel screws for the fixation of displaced medial malleolar fractures.
引用
收藏
页码:319 / 324
页数:6
相关论文
共 15 条
  • [1] BIODEGRADABLE INTERNAL-FIXATION FOR MALLEOLAR FRACTURES - A PROSPECTIVE RANDOMIZED TRIAL
    BOSTMAN, O
    VAINIONPAA, S
    HIRVENSALO, E
    MAKELA, A
    VIHTONEN, K
    TORMALA, P
    ROKKANEN, P
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (04): : 615 - 619
  • [2] BOSTMAN O, 1989, CLIN ORTHOPAEDICS, V238, P195
  • [3] OSTEOLYTIC CHANGES ACCOMPANYING DEGRADATION OF ABSORBABLE FRACTURE FIXATION IMPLANTS
    BOSTMAN, OM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (04): : 679 - 682
  • [4] ABSORBABLE IMPLANTS FOR THE FIXATION OF FRACTURES
    BOSTMAN, OM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) : 148 - 153
  • [5] CHEN E, 1992, T ORTHOP RES SOC, V17, P87
  • [6] EITENMULLER J, 1990, 53 JAHR TAG DTSCH GE
  • [7] EWERS R, 1990, Facial Plastic Surgery, V7, P206, DOI 10.1055/s-2008-1064684
  • [8] FROKJAER J, 1990, ACTA ORTHOP SCA S237, V61, P45
  • [9] A SCORING SCALE FOR SYMPTOM EVALUATION AFTER ANKLE FRACTURE
    OLERUD, C
    MOLANDER, H
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1984, 103 (03) : 190 - 194
  • [10] OLERUD C, 1986, CLIN ORTHOPAEDICS, V206, P253