A METHOD FOR MEASURING THE STRUCTURAL-PROPERTIES OF THE RAT MANDIBLE

被引:12
作者
ELOVIC, RP [1 ]
HIPP, JA [1 ]
HAYES, WC [1 ]
机构
[1] HARVARD UNIV,SCH DENT MED,DEPT RESTORAT DENT,BOSTON,MA 02115
关键词
MANDIBLE; MECHANICAL PROPERTIES; RAT MODEL; BIOMECHANICS; BONE MECHANICS;
D O I
10.1016/0003-9969(94)90054-X
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The rat mandible has been used to study fractures, ridge augmentation, bone defects, and the effects of cryosurgery, all of which affect the structural properties of the mandible. The only previously described mechanical test of the rat mandible used three-point bending with a piece of foam placed between the lingual surface of the mandible and the support. The accuracy and reproducibility of this test were not determined. Two different, three-point bending tests for characterizing the structural properties of the rat mandible have now been evaluated. Acrylic specimens representing three different-sized mandibles were tested in three-point bending with either potted ends or foam interposed between the specimen and the outer load points. Flexural stiffness and failure load were compared against data from a conventional three-point bending test. In addition; five paired halves of 90- and 210-day-old rat mandibles were tested either with interposed foam or with potted ends and the mean coefficients of variation of the stiffness and failure loads were determined. Failure loads of the acrylic specimens with the potted and foam methods were significantly higher (50 and 10%, respectively; p < 0.05) than with the conventional method. The stiffness of the acrylic specimens with the potted and foam methods was significantly different (75% higher and 21% lower, respectively; p < 0.05) than with the conventional test. In addition, there was no difference between the coefficient of variation in stiffness (26 + 11%) or failure load (10 + 4%) measured with the foam test and the comparable values (16 + 11%) and (18 + 13%) in the potted test. Thus it appears that the foam test more accurately reflects the stiffness and failure load of the acrylic specimens than the potted test. Although there was no difference in the coefficients of variation in the potted and foam tests, the technical difficulties associated with potting indicate that the foam test is a better method for testing the structural properties of the rat mandible. The objective of this experiment was to establish a method for accurately measuring the structural properties of the rat mandible and for detecting differences in structural properties between different treatment groups.
引用
收藏
页码:1029 / 1033
页数:5
相关论文
共 9 条
[1]  
Beer F. P., 1992, MECH MATER
[2]   EFFECT OF HYDROXYLAPATITE, TRICALCIUM PHOSPHATE, AND COLLAGEN ON THE HEALING OF DEFECTS IN THE RAT MANDIBLE [J].
BELL, R ;
BEIRNE, OR .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1988, 46 (07) :589-594
[3]  
ELOVIC RP, IN PRESS J DENT RES
[4]  
Fisher AD, 1977, BR J ORAL SURG, V15, P215
[5]   EXPERIMENTAL MANDIBULAR FRACTURE - STUDIES ON BONE REPAIR AND REMODELING [J].
GRANSTROM, G ;
NILSSON, LP .
SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1987, 21 (02) :159-165
[6]   INDUCED OSTEOGENESIS IN THE REPAIR OF EXPERIMENTAL MANDIBULAR DEFECTS IN RATS [J].
KABAN, LB ;
GLOWACKI, J .
JOURNAL OF DENTAL RESEARCH, 1981, 60 (07) :1356-1364
[7]   AUGMENTATION OF RAT MANDIBULAR RIDGE WITH DEMINERALIZED BONE IMPLANTS [J].
KABAN, LB ;
GLOWACKI, J .
JOURNAL OF DENTAL RESEARCH, 1984, 63 (07) :998-1002
[8]   OBSERVATIONS ON THE EFFECTS OF 2 CERAMICS ON THE STRENGTH OF BONE SUBJECTED TO CRYOSURGERY [J].
MCCORD, JF ;
BRADLEY, PF .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1989, 27 (03) :217-223
[9]  
PELKER R R, 1984, Journal of Orthopaedic Research, V1, P405