DELAYED FATAL PULMONARY HEMORRHAGE COMPLICATING USE OF A BALLOON FLOTATION CATHETER

被引:21
作者
KLIBANER, MI
HAYES, JA
DOBNICK, D
MCCORMICK, JR
机构
[1] BOSTON CITY HOSP,MALLORY INST PATHOL,BOSTON,MA 02118
[2] UNIV HOSP BOSTON,DEPT PATHOL,BOSTON,MA 02118
[3] UNIV HOSP BOSTON,MED CTR,DEPT ANESTHESIOL,BOSTON,MA 02118
[4] UNIV HOSP BOSTON,MED CTR,DEPT CARDIOTHORAC SURG,BOSTON,MA 02118
关键词
D O I
10.1177/000331978503600604
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
引用
收藏
页码:358 / 362
页数:5
相关论文
共 5 条
  • [1] FATAL PULMONARY HEMORRHAGE COMPLICATING USE OF A FLOW-DIRECTED BALLOON-TIPPED CATHETER IN A PATIENT RECEIVING ANTICOAGULANT THERAPY
    GOLDEN, MS
    PINDER, T
    ANDERSON, WT
    CHEITLIN, MD
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1973, 32 (06) : 865 - 867
  • [2] LEMEN R, 1975, NEW ENGL J MED, V292, P211
  • [3] PAULSON DM, 1980, J THORAC CARDIOV SUR, V80, P453
  • [4] PITFALLS OF SWAN-GANZ CATHETERIZATION
    SHIN, B
    AYELLA, RJ
    MCASLAN, TC
    [J]. CRITICAL CARE MEDICINE, 1977, 5 (03) : 125 - 127
  • [5] SPRUNG CL, 1983, PULMONARY ARTERY CAT