摘要
A radiolucent fragment of a fractured central venous catheter embolized to the right heart resulting in life-threatening dysrhythmias in a middle-aged male patient who had undergone orthotopic liver transplantation 1 day earlier. The fragment was removed via the right transjugular route using sonographic guidance to entrap the fragment with a brightly echogenic snare. The technique described protects the caval anastomoses in the liver transplant recipient and overcomes the limitation of fluoroscopy in removing radiolucent bodies.
引用
收藏
页码:58 / 60
页数:3
相关论文
共 11 条
[1]  
Hubert J.W., Krone R.J., Shatz B.A., Susman N., An improved snare system for the nonsurgical retrieval of intravascular foreign bodies, Cathet Cardiovasc Diagn, 6, pp. 405-411, (1980)
[2]  
Gerlock A.J., Mirfakhraee M., Retrieval of intravascular foreign bodies, J Thorac Imag, 2, 2, pp. 52-60, (1987)
[3]  
Woo V.L., Gerber A.M., Scheible W., Seo K.W., Bookstein J.J., Leopold G.R., Real-time ultrasound guidance for percutaneous transluminal retrieval of nonopaque intravascular catheter fragment, AJR, 133, pp. 760-761, (1979)
[4]  
Glatter T.R., Scott A.C., Early G., Percutaneous removal of intracardiac catheter fragment. Unique internal jugular venous approach, Am Heart J, 180, 2, pp. 408-410, (1984)
[5]  
Neumann H.P.H., Hofmann T., Koester W., Billmann P., Kauffman G.W., Extraction of an intracardial catheter embolus using combined radiography and transesophageal echocardiography, Clin Cardiol, 11, pp. 427-429, (1988)
[6]  
Greenfield L.J., Crute S.L., Retrieval of the Greefield<sup>*</sup> vena caval filter, Surgery, 88, 5, pp. 719-722, (1980)
[7]  
Yedlicka J.W., Carlson J.E., Hunter D.W., Castaneda-Zuniga W.R., Amplatz K., Nitinol gooseneck snare for removal of foreign bodies: Experimental study and clinical evaluation, Radiology, 178, 3, pp. 691-693, (1991)
[8]  
Fisher R.G., Ferreyro R., Evaluation of current techniques for nonsurgical removal of intravascular iatrogenic foreign bodies, Am J Roentgenol, 130, pp. 541-548, (1978)
[9]  
Blair E., Hunziker R., Flanagan M.E., Catheter embolism, Surgery, 67, pp. 457-461, (1970)
[10]  
Bernhardt L.C., Wegner G.P., Mendenhall J.T., Intravenous catheter embolization to the pulmonary artery, Chest, 57, pp. 329-332, (1970)