A COMPARISON BETWEEN ELECTROMYOGRAPHY AND ANAL ENDOSONOGRAPHY IN MAPPING EXTERNAL ANAL-SPHINCTER DEFECTS

被引:120
作者
LAW, PJ
KAMM, MA
BARTRAM, CI
机构
[1] ST MARKS HOSP,DEPT RADIOL,CITY RD,LONDON EC1V 2PS,ENGLAND
[2] ST MARKS HOSP,DEPT MED,LONDON EC1V 2PS,ENGLAND
关键词
Anal sphincters; Anus; Electromyography; Incontinence; Ultrasound;
D O I
10.1007/BF02156260
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Mapping of the external anal sphincter by anal endosonography was compared with the electromyographic findings in 15 patients with fecal incontinence after perineal trauma. Both examinations showed no defect in three patients. In the 12 patients with muscle defects, there was agreement on the quadrant involved in all patients. In seven patients, there was total agreement in the hours of the defect, in four there was a one hour discrepancy, and in one there was a two-hour difference in the measured defect. Correlation between the two techniques was high (r =0.96;P<0.01). Anal endosonography is better tolerated by patients than electromyographic mapping and is a useful technique for assessing posttraumatic defects of the external anal sphincter. © 1990 American Society of Colon and Rectal Surgeons.
引用
收藏
页码:370 / 373
页数:4
相关论文
共 4 条