INTERSEED EFFECTS ON DOSE FOR I-125 BRACHYTHERAPY IMPLANTS

被引:33
作者
MEIGOONI, AS
MELI, JA
NATH, R
机构
[1] Yale University, School of Medicine, Department of Therapeutic Radiology, New Haven, Connecticut 06510
关键词
I-125; BRACHYTHERAPY; SOURCE-TO-SOURCE SHIELDING; DOSIMETRY; TLD;
D O I
10.1118/1.596871
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Dose calculations in multiseed brachytherapy implants are done by adding the contribution of each individual seed and by assuming that radiation from each seed is unaffected by the presence of the other seeds. To test the validity of this assumption, dose measurements with various configurations of multiseed implants of I-125 model 6702 and I-125 model 6711 sources were performed. For a linear configuration of three I-125 model 6702 seeds at 1-cm separation, with their transverse axes coincident, doses at distances of 3.05 and 5.09 cm from the center along the transverse axis were found to be about 8% lower than the sum of doses from the three individual seeds. However, for three seeds at 1-cm intervals with their longitudinal axes coincident, doses at 3.05 and 5.09 cm distances from the center along the longitudinal axis were found to be about equal to the dose sums from individual seeds. These initial experiments indicated that the magnitude of the interseed effect depends upon the orientation of the seed relative to each other in an implant. To evaluate the importance of this interseed effect for multiseed configurations of I-125 model 6702 and I-125 model 6711 seeds, dose rates at various distances from a two-plane implant (each plane containing a 3 x 3 array of sources in a 1-cm spacing square grid) were measured in a Solid Water phantom with LiF TLDs. These measurements were carried out in two different planes at different orientations relative to the implant. The average values of the interseed effect at distances ranging from 1 to 7 cm outside the implant were observed to be about the same for I-125 model 6702 and model 6711 sources. The mean value of the interseed effect was 6% and the maximum was 12%. On the whole, the interseed effect reduces the dose at the periphery of the iodine implant by 6%.
引用
收藏
页码:385 / 390
页数:6
相关论文
共 8 条
[1]
Anderson LL, 1990, INTERSTITIAL BRACHYT
[2]
BERKLEY LW, 1981, AM ASS PHYSICISTS ME, V7, P38
[3]
THE ACCURACY OF SINGLE-SEED DOSE SUPERPOSITION FOR I125 IMPLANTS [J].
BURNS, GS ;
RAESIDE, DE .
MEDICAL PHYSICS, 1989, 16 (04) :627-631
[4]
THE 3-DIMENSIONAL DOSE DISTRIBUTION OF I-125 SEEDS IN TISSUE [J].
HARTMANN, GH ;
SCHLEGEL, W ;
SCHARFENBERG, H .
PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (06) :693-699
[5]
A COMPARISON OF SOLID PHANTOMS WITH WATER FOR DOSIMETRY OF I125 BRACHYTHERAPY SOURCES [J].
MEIGOONI, AS ;
MELI, JA ;
NATH, R .
MEDICAL PHYSICS, 1988, 15 (05) :695-701
[6]
NATH R, 1987, AAPM21 AM I PHYS REP
[7]
RESPONSE OF LIF POWDER TO I-125 PHOTONS [J].
WEAVER, KA .
MEDICAL PHYSICS, 1984, 11 (06) :850-854
[8]
THEORETICAL EVALUATION OF DOSE DISTRIBUTIONS IN WATER ABOUT MODELS 6711 AND 6702 I125 SEEDS [J].
WILLIAMSON, JF ;
QUINTERO, FJ .
MEDICAL PHYSICS, 1988, 15 (06) :891-897