AORTIC-VALVE REPLACEMENT WITH A STENTLESS PORCINE AORTIC-VALVE - A 6-YEAR EXPERIENCE

被引:69
作者
DAVID, TE
FEINDEL, CM
BOS, J
SUN, Z
SCULLY, HE
RAKOWSKI, H
机构
[1] TORONTO HOSP, DIV CARDIOVASC SURG, TORONTO, ON, CANADA
[2] TORONTO HOSP, DIV CARDIOL, TORONTO, ON, CANADA
[3] UNIV TORONTO, TORONTO, ON, CANADA
关键词
D O I
10.1016/S0022-5223(94)70144-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A stentless porcine aortic valve was used for aortic valve replacement in 123 patients from 1987 to 1993. The mean age of 86 men and 37 women was 61 +/- 12 years. Most patients had aortic stenosis; one-third had coronary artery disease and six had mitral valve disease. The stentless valve was secured in the subcoronary position by the same technique used for a freehand aortic valve homograft. The size of valve was based largely on the diameter of the sinotubular junction of the aortic root. The mean valve size was 26.5 mm (range 19 to 29 mm) and 87 % were 25 mm or larger. Two operative deaths occurred, one the result of myocardial infarction and the other the result of infective endocarditis. Patients hare been followed up from 3 to 77 months, mean 22 months. Three late deaths, none related to the valve, have occurred. The actuarial survival at 6 years was 91% +/- 4%. Four transient cerebral ischemic events have occurred, but two patients had extr acranial cerebrovascular disease. One patient had endocarditis late in the postoperative period and required reoperation. All patients had Doppler echocardiographic studies before discharge from the hospital, 3 to 6 months later and annually. Only 15 patients have aortic insufficiency, trivial in 6 and mild in 9. The peak and mean systolic gradients decreased significantly during the first 3 to 6 months after implantation (p < 0.001), and the effective valve areas increased significantly during this time interval (p < 0.001). This improvement in valve hemodynamics is believed to be due to remodeling of the aortic root and regression of left ventricular hypertrophy. The results of aortic valve replacement with this stentless bioprosthesis have been excellent and justify its continued use in older patients.
引用
收藏
页码:1030 / 1036
页数:7
相关论文
共 18 条
[1]  
ANGELL WW, 1989, J THORAC CARDIOV SUR, V98, P48
[2]  
BARRATT-BOYES B G, 1964, Thorax, V19, P131, DOI 10.1136/thx.19.2.131
[3]  
BINET JP, 1965, LANCET, V2, P1275
[4]   BIOLOGICAL FACTORS AFFECTING LONG-TERM RESULTS OF VALVULAR HETEROGRAFTS [J].
CARPENTIER, A ;
LEMAIGRE, G ;
ROBERT, L ;
CARPENTIER, S ;
DUBOST, C ;
GERBODE, F .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1969, 58 (04) :467-+
[5]   STENTLESS PORCINE AND PERICARDIAL VALVE IN AORTIC POSITION [J].
CASABONA, R ;
DEPAULIS, R ;
ZATTERA, GF ;
DISUMMA, M ;
BOTTONE, W ;
STACCHINO, C ;
VRANDECIC, MOP ;
MOREA, M .
ANNALS OF THORACIC SURGERY, 1992, 54 (04) :681-685
[6]  
David T E, 1988, J Card Surg, V3, P501, DOI 10.1111/j.1540-8191.1988.tb00444.x
[7]   CLINICAL AND HEMODYNAMIC ASSESSMENT OF THE HANCOCK-II BIOPROSTHESIS [J].
DAVID, TE ;
ARMSTRONG, S ;
SUN, Z .
ANNALS OF THORACIC SURGERY, 1992, 54 (04) :661-668
[8]  
DAVID TE, 1990, J THORAC CARDIOV SUR, V99, P113
[9]  
DURAN CG, 1962, LANCET, V2, P488
[10]  
Grande K J, 1993, ASAIO J, V39, P918, DOI 10.1097/00002480-199310000-00017