LONG-TERM AMBULATORY MONITORING OF INDIRECT ARTERIAL BLOOD-PRESSURE USING A VOLUME-OSCILLOMETRIC METHOD

被引:12
作者
YAMAKOSHI, K [1 ]
KAWARADA, A [1 ]
KAMIYA, A [1 ]
SHIMAZU, H [1 ]
ITO, H [1 ]
机构
[1] KYORIN UNIV,SCH MED,DEPT PHYSIOL,MITAKA,TOKYO 181,JAPAN
关键词
COMPUTERS; MICROPROCESSOR - Applications - DATA STORAGE; DIGITAL - Medical Applications - INTEGRATED CIRCUITS; DIGITAL - Medical Applications - PRESSURE MEASUREMENT - Medical Applications;
D O I
10.1007/BF02448934
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A new portable instrument equipped with a microprocessor was designed for the long-term ambulatory monitoring of indirect arterial pressure in the human finger at desired intervals using a volume-oscillometric technique. All the necessary procedures such as (1) programmed control of cuff pressure, (2) detection of the systolic end-point and the point of maximum amplitude of arterial volume pulsations, (3) reading of the cuff pressures corresponding to these two points, (4) its processing and (5) recording of the systolic and mean pressure together with heart rate on a digital memory integrated circuit were performed automatically. After the monitoring, the data were reproduced and analyzed by a conventional personal computer. Simultaneous comparison of the data with direct measurement, operation and evaluation of this instrument, and ambulatory monitoring were carried out.
引用
收藏
页码:459 / 465
页数:7
相关论文
共 11 条
[1]  
BACHMANN K, 1981, BIOTELEMETRY PATIENT, V8, P1
[2]  
GEDDES LA, 1970, DIRECT INDIRECT MEAS, P196
[3]   PORTABLE BLOOD PRESSURE RECORDER ACCURACY AND PRELIMINARY USE IN EVALUATING INTRADAILY VARIATIONS IN PRESSURE [J].
HINMAN, AT ;
ENGEL, BT ;
BICKFORD, AF .
AMERICAN HEART JOURNAL, 1962, 63 (05) :663-&
[4]   NON-INVASIVE AUTOMATIC-DETERMINATION OF MEAN ARTERIAL-PRESSURE [J].
RAMSEY, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1979, 17 (01) :11-18
[5]   IMPROVED FULLY AUTOMATIC PORTABLE BLOOD-PRESSURE RECORDER [J].
SCHNEIDER, RA ;
KIMMELL, GO ;
VANMETER, AP .
JOURNAL OF APPLIED PHYSIOLOGY, 1974, 37 (05) :776-779
[6]   A FULLY AUTOMATIC PORTABLE BLOOD PRESSURE RECORDER [J].
SCHNEIDER, RA .
JOURNAL OF APPLIED PHYSIOLOGY, 1968, 24 (01) :115-+
[7]   NEW OSCILLOMETRIC METHOD FOR INDIRECT MEASUREMENT OF SYSTOLIC AND MEAN ARTERIAL-PRESSURE IN THE HUMAN FINGER .2. CORRELATION STUDY [J].
YAMAKOSHI, K ;
SHIMAZU, H ;
SHIBATA, M ;
KAMIYA, A .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1982, 20 (03) :314-318
[8]   NEW OSCILLOMETRIC METHOD FOR INDIRECT MEASUREMENT OF SYSTOLIC AND MEAN ARTERIAL-PRESSURE IN THE HUMAN FINGER .1. MODEL EXPERIMENT [J].
YAMAKOSHI, K ;
SHIMAZU, H ;
SHIBATA, M ;
KAMIYA, A .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1982, 20 (03) :307-313
[9]   INDIRECT MEASUREMENT OF INSTANTANEOUS ARTERIAL BLOOD-PRESSURE IN THE HUMAN FINGER BY THE VASCULAR UNLOADING TECHNIQUE [J].
YAMAKOSHI, K ;
SHIMAZU, H ;
TOGAWA, T .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (03) :150-155
[10]   NON-INVASIVE AUTOMATIC MONITORING OF INSTANTANEOUS ARTERIAL BLOOD-PRESSURE USING THE VASCULAR UNLOADING TECHNIQUE [J].
YAMAKOSHI, K ;
KAMIYA, A ;
SHIMAZU, H ;
ITO, H ;
TOGAWA, T .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1983, 21 (05) :557-565