QUANTITATIVE ASSESSMENT OF SURFACE-ROUGHNESS USING BACKSCATTERED ULTRASOUND - THE EFFECTS OF FINITE SURFACE CURVATURE

被引:36
作者
CHIANG, EH
ADLER, RS
MEYER, CR
RUBIN, JM
DEDRICK, DK
LAING, TJ
机构
[1] UNIV MICHIGAN,MED CTR,DEPT RADIOL,1500 E MED CTR,ANN ARBOR,MI 48109
[2] UNIV MICHIGAN,MED CTR,DEPT SURG,ORTHOPAED RES LABS,ORTHOPAED SECT,ANN ARBOR,MI 48109
[3] UNIV MICHIGAN,MED CTR,DEPT INTERNAL MED,DIV RHEUMATOL,ANN ARBOR,MI 48109
关键词
ACOUSTICS; ULTRASOUND; ULTRASONIC SCANNING; ULTRASONIC BACKSCATTER; ROUGHNESS; SURFACE CURVATURE; ARTICULAR CARTILAGE ROUGHNESS; OSTEOARTHRITIS;
D O I
10.1016/0301-5629(94)90077-9
中图分类号
O42 [声学];
学科分类号
070206 [声学]; 082403 [水声工程];
摘要
We have previously described a technique to quantify surface fibrillatory changes in osteoarthritic articular cartilage. In that study, the angular distribution of the scattered acoustic field from an insonifying source directly related to the distribution of surface fibrillatory changes. In the current study, we demonstrate a more sensitive method to quantify surface roughness, the effect of global surface curvature in estimating surface roughness and the utility of using focused transducers in circumventing this potential problem for in vivo work. Phantoms composed of acrylic rods with and without sandpaper grit (about 15 to 72 mum, mean particle size) applied to the surface were scanned. A more robust angular scattering technique to measure the angle dependent data was employed, in which the integrated squared pressure amplitude over a finite time window (mean power) was measured as a function of incident acoustic angle for varying surface roughnesses and radii of curvature. We show that the potential dynamic range for making roughness discriminations diminishes with decreasing radius of curvature of the acrylic rod phantoms using an unfocused transducer. This effect is minimized with use of a focused transducer. Roughness effects are most evident at sufficiently large angles where incoherent scattering dominates. We conclude that the roughness of cylindrically curved surfaces can be quantitatively assessed using a focused ultrasound beam at sufficiently large incident angles, given that the focal spot size is sufficiently smaller than the radius of curvature of the surface.
引用
收藏
页码:123 / 135
页数:13
相关论文
共 11 条
[1]
QUANTITATIVE ASSESSMENT OF CARTILAGE SURFACE-ROUGHNESS IN OSTEOARTHRITIS USING HIGH-FREQUENCY ULTRASOUND [J].
ADLER, RS ;
DEDRICK, DK ;
LAING, TJ ;
CHIANG, EH ;
MEYER, CR ;
BLAND, PH ;
RUBIN, JM .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1992, 18 (01) :51-58
[3]
CHARACTERIZING PULSES REFLECTED FROM ROUGH SURFACES USING ULTRASOUND [J].
BOZMA, O ;
KUC, R .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1991, 89 (06) :2519-2531
[4]
de Billy M., 1976, IEEE Transactions on Sonics and Ultrasonics, VSU-23, P356, DOI 10.1109/T-SU.1976.30891
[6]
OSTEOARTHROTIC ARTICULAR-CARTILAGE LESIONS OF FEMORAL-HEAD OBSERVED IN SCANNING ELECTRON-MICROSCOPE [J].
MINNS, RJ ;
STEVEN, FS ;
HARDINGE, K .
JOURNAL OF PATHOLOGY, 1977, 122 (02) :63-+
[7]
QUENTIN G, 1975, ULTRASONICS S P, P102
[8]
RAYLEIGH, 1945, THEORY SOUND
[9]
ACOUSTIC STUDIES OF BROAD-BAND SCATTERING FROM A MODEL ROUGH-SURFACE [J].
THORNE, PD ;
PACE, NG .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1984, 75 (01) :133-144