AMPEROMETRIC BIOSENSOR FOR RAPID MEASUREMENT OF 3-HYDROXYBUTYRATE IN UNDILUTED WHOLE-BLOOD AND PLASMA

被引:27
作者
MCNEIL, CJ
SPOORS, JA
COOPER, JM
ALBERTI, KGMM
MULLEN, WH
机构
[1] UNIV NEWCASTLE UPON TYNE,SCH MED,DEPT MED,NEWCASTLE TYNE NE2 4HH,ENGLAND
[2] CAMBRIDGE LIFE SCI PLC,ELY CB7 4DT,ENGLAND
基金
英国医学研究理事会;
关键词
Biosensor; Blood; Enzyme electrodes; Hydroxybutyrate; Plasma;
D O I
10.1016/S0003-2670(00)83906-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, rapid (< 30 s) electrochemical method for the determination of 3-hydroxybutyrate in whole blood or plasma is described, which uses NAD+-dependent d-3-hydroxybutyrate dehydrogenase immobilized at novel platinized carbon electrodes. The steady-state oxidation current produced by enzymatically generated NADH is measured at + 150 mV vs. Ag/AgCl. Enzyme electrodes produced by direct adsorption were stable for at least 3 months. Undiluted whole blood measurement with the sensor was compared with routine spectrophotometric analysis of plasma and perchloric acid extracts of whole blood. © 1990.
引用
收藏
页码:99 / 105
页数:7
相关论文
共 21 条
  • [1] ENZYMATIC DETERMINATION OF GLUCOSE IN A FLOW SYSTEM BY CATALYTIC-OXIDATION OF THE NICOTINAMIDE COENZYME AT A MODIFIED ELECTRODE
    APPELQVIST, R
    MARKOVARGA, G
    GORTON, L
    TORSTENSSON, A
    JOHANSSON, G
    [J]. ANALYTICA CHIMICA ACTA, 1985, 169 (MAR) : 237 - 247
  • [2] BENNETTO HP, 1988, Patent No. 289344
  • [3] BENNETTO HP, 1988, Patent No. 8700365
  • [4] PURIFICATION AND PROPERTIES OF CRYSTALLINE 3-HYDROXYBUTYRATE DEHYDROGENASE FROM RHODOPSEUDOMONAS SPHEROIDES
    BERGMEYER, HU
    GAWEHN, K
    KLOTZSCH, H
    KREBS, HA
    WILLIAMSON, DH
    [J]. BIOCHEMICAL JOURNAL, 1967, 102 (02) : 423 - +
  • [5] ELVING PJ, 1982, BIOELECTROCH BIOENER, V9, P365, DOI 10.1016/0302-4598(82)80026-3
  • [6] FOSTER DW, 1983, NEW ENGL J MED, V309, P159
  • [7] CHEMICALLY MODIFIED ELECTRODES FOR THE ELECTROCATALYTIC OXIDATION OF NICOTINAMIDE COENZYMES
    GORTON, L
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 : 1245 - 1258
  • [8] GRONOW M, 1985, CLIN BIOCH NEARER PA, P108
  • [9] SENSITIVE AND SIMPLIFIED METHOD FOR THE DIFFERENTIAL DETERMINATION OF SERUM LEVELS OF KETONE-BODIES
    HARANO, Y
    KOSUGI, K
    HYOSU, T
    UNO, S
    ICHIKAWA, Y
    SHIGETA, Y
    [J]. CLINICA CHIMICA ACTA, 1983, 134 (03) : 327 - 336
  • [10] DIRECT AUTOMATED-ASSAY METHOD FOR SERUM OR URINE LEVELS OF KETONE-BODIES
    HARANO, Y
    OHTSUKI, M
    IDA, M
    KOJIMA, H
    HARADA, M
    OKANISHI, T
    KASHIWAGI, A
    OCHI, Y
    UNO, S
    SHIGETA, Y
    [J]. CLINICA CHIMICA ACTA, 1985, 151 (02) : 177 - 183