IMPEDANCE TOMOGRAPHY - COMPUTATIONAL ANALYSIS BASED ON FINITE-ELEMENT MODELS OF A CYLINDER AND A HUMAN THORAX

被引:3
作者
SHAHIDI, AV
GUARDO, R
SAVARD, P
机构
[1] ECOLE POLYTECH,INST BIOMED ENGN,MONTREAL,PQ H3C 3A7,CANADA
[2] UNIV MONTREAL,MONTREAL,PQ,CANADA
关键词
IMPEDANCE IMAGING; EDEMA MONITORING; FINITE ELEMENT MODELING;
D O I
10.1007/BF02368301
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A direct image reconstruction method of electrical impedance tomography (EIT) is evaluated using three-dimensional (3-D) finite element models of cylindrical and torso-shaped volume conductors. The cylindrical model is used to examine the effect of electrode configurations and the sensitivity to off-plane objects and to noise in the measured data. It is also used to validate the modeling procedures by comparison with experimental data acquired from a similar cylindrical tank filled with saline. Simulation results show only minor differences in performance between the various electrode configurations. In the second part, a realistic human thorax model constructed from CT images is used to evaluate monitoring of pulmonary edema by EIT. The conductivity, volume, and vertical position of an abnormal region in the lungs are varied to simulate the progress of edema. Dynamic EIT images are reconstructed from data computed for the inhomogeneous thorax (heart and lungs) as the reference set and a realistic amount of noise is added to reproduce the conditions in which the technique would be used in practice. Simulation results show that a 10 ml edema region with a conductivity equal to that of blood can be detected at a 40 dB signal-to-noise ratio (SNR). Detection of a smaller volume, in the order of 2 ml, should be possible by improving either the instrumentation to achieve 60 dB SNR or the performance of reconstruction algorithms.
引用
收藏
页码:61 / 69
页数:9
相关论文
共 24 条
[1]   APPLIED POTENTIAL TOMOGRAPHY [J].
BARBER, DC ;
BROWN, BH .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1984, 17 (09) :723-733
[2]  
BARBER DC, 1985, 9TH P INT C INF P ME, P106
[3]  
BROWN BH, 1992, 14TH P ANN INT C IEE, P1710
[4]   INVIVO IMAGING OF CARDIAC RELATED IMPEDANCE CHANGES [J].
EYUBOGLU, BM ;
BROWN, BH ;
BARBER, DC .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1989, 8 (01) :39-45
[5]   SPECIFIC RESISTANCE OF BIOLOGICAL MATERIAL-A COMPENDUM OF DATA FOR BIOMEDICAL ENGINEER AND PHYSIOLOGIST [J].
GEDDES, LA ;
BAKER, LE .
MEDICAL & BIOLOGICAL ENGINEERING, 1967, 5 (03) :271-&
[6]   AN EXPERIMENTAL-STUDY IN ELECTRICAL-IMPEDANCE TOMOGRAPHY USING BACKPROJECTION RECONSTRUCTION [J].
GUARDO, R ;
BOULAY, C ;
MURRAY, B ;
BERTRAND, M .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (07) :617-627
[7]  
GUARDO R, 1989, 11TH P ANN INT C IEE, P468
[8]   ITERATIVE RECONSTRUCTION METHODS USING REGULARIZATION AND OPTIMAL CURRENT PATTERNS IN ELECTRICAL-IMPEDANCE TOMOGRAPHY [J].
HUA, P ;
WOO, EJ ;
WEBSTER, JG ;
TOMPKINS, WJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (04) :621-628
[9]   ELECTRICAL-IMPEDANCE TOMOGRAPHY OF TRANSLATIONALLY UNIFORM CYLINDRICAL OBJECTS WITH GENERAL CROSS-SECTIONAL BOUNDARIES [J].
IDER, YZ ;
GENCER, NG ;
ATALAR, E ;
TOSUN, H .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (01) :49-59
[10]  
Isaacso D., 1991, CONT MATH, V122, P29