SOME LIMITATIONS IN USE OF PLASTIC AND DYED PLASTIC DOSIMETERS

被引:42
作者
MILLER, A [1 ]
BJERGBAKKE, E [1 ]
MCLAUGHLIN, WL [1 ]
机构
[1] DANISH ATOM ENERGY COMM,ACCELERATOR DEPT,RES ESTAB RISO,DK-4000 ROSKILDE,DENMARK
来源
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES | 1975年 / 26卷 / 10期
关键词
PLASTICS; -; Irradiation;
D O I
10.1016/0020-708X(75)90079-4
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Several practical plastic and dyed plastic dosimeters were examined under irradiation conditions similar to those used for radiation processing of materials. Cellulose triacetate, polymethyl methacrylate, polyvinyl chloride, dyed polymethyl methacrylate, dyed Cellophane and dyed Nylon were given fractionated and uninterrupted absorbed doses in the megarad range with **6**0Co gamma -rays and 10 MeV electron beams. It was found that with some systems, differences in radiation response due to dose-rate and temperature dependence can cause large systematic errors in dose interpretation. Tables, equations, and graphs show data.