MOLECULAR AND PARTICULATE DEPOSITIONS FOR REGIONAL MYOCARDIAL FLOWS IN SHEEP

被引:74
作者
BASSINGTHWAIGHTE, JB [1 ]
MALONE, MA [1 ]
MOFFETT, TC [1 ]
KING, RB [1 ]
CHAN, IS [1 ]
LINK, JM [1 ]
KROHN, KA [1 ]
机构
[1] UNIV WASHINGTON,DEPT RADIOL,SEATTLE,WA 98195
关键词
2-iododesmethylimipramine; flow heterogeneity; microsphere deposition; molecular microsphere; regional myocardial blood flow; sheep;
D O I
10.1161/01.RES.66.5.1328
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The deposition of microspheres in small tissue regions is not strictly flow dependent. In comparison with the soluble flow marker 2-iododesmethylimipramine (IDMI), deposition of 16.5-μm microspheres was mildly but systematically biased into high flow regions of rabbit hearts (Bassingthwaighte JB, Malone MA, Moffett T-C, King RB, Little SE, Link JM, Krohn KA. Am J Physiol 1987;253 (Heart Circ Physiol 22):H184-H193). To examine the possibility of bias in larger hearts, a similar study was undertaken in sheep. 141Ce- and 103Ru-labeled 16.5-μm microspheres in one syringe and 125I- and 131I-DMI in another syringe were injected simultaneously into the left atrium of five open-chest sheep while obtaining reference blood samples from the femoral artery. In six other sheep, one microsphere type and one IDMI were used. Hearts were removed 1 minute after injection, cut into approximately 254 pieces averaging 217 mg, and regional deposition densities calculated for each tracer from the isotopic counts. Correlations in the five animals between the two differently labeled IDMIs and between the two microspheres were both ≥0.98. In all 11 sheep, scatter plots of microsphere deposition densities versus IDMI densities showed that differences between microspheres and IDMI had substantially more scatter (0.84 < r < 0.98) but were not random. Microsphere depositions tended to be lower than IDMI depositions in low flow regions and higher in high flow regions, in accord with the expected bias that at a bifurcation a microsphere is most likely to enter the branch with higher flow. There was less bias ascribable to endomyocardial/epicardial maldistribution. Thus, while microsphere depositions appear to err systematically with respect to flow when the regions of interest are small enough that the diameters of their arterioles are only a few times those of the microspheres, microspheres are, in sheep as in rabbits, adequate for estimating regional flows.
引用
收藏
页码:1328 / 1344
页数:17
相关论文
共 33 条
[1]   INCREASED NUMBER OF MYOCARDIAL BLOOD-FLOW MEASUREMENTS WITH RADIONUCLIDE-LABELED MICROSPHERES [J].
BAER, RW ;
PAYNE, BD ;
VERRIER, ED ;
VLAHAKES, GJ ;
MOLODOWITCH, D ;
UHLIG, PN ;
HOFFMAN, JIE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1984, 246 (03) :H418-H434
[2]   ESTIMATION OF CORONARY BLOOD FLOW BY WASHOUT OF DIFFUSIBLE INDICATORS [J].
BASSINGT.JB ;
STRANDEL.T ;
DONALD, DE .
CIRCULATION RESEARCH, 1968, 23 (02) :259-&
[3]  
BASSINGTHWAIGHT.JB, 1984, HDB PHYSL 2, V4, P549
[4]  
Bassingthwaighte J. B., 1972, MYOCARDIAL BLOOD FLO, P197
[5]   PHYSIOLOGY AND THEORY OF TRACER WASHOUT TECHNIQUES FOR ESTIMATION OF MYOCARDIAL BLOOD-FLOW - FLOW ESTIMATION FROM TRACER WASHOUT [J].
BASSINGTHWAIGHTE, JB .
PROGRESS IN CARDIOVASCULAR DISEASES, 1977, 20 (03) :165-189
[6]   VALIDITY OF MICROSPHERE DEPOSITIONS FOR REGIONAL MYOCARDIAL FLOWS [J].
BASSINGTHWAIGHTE, JB ;
MALONE, MA ;
MOFFETT, TC ;
KING, RB ;
LITTLE, SE ;
LINK, JM ;
KROHN, KA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 253 (01) :H184-H193
[7]  
BECKER L, 1974, J NUCL MED, V15, P969
[8]  
BLIXT A, 1987, INT J MICROCIRC, V6, P273
[9]   A MATHEMATICAL-ANALYSIS OF THE INFLUENCE OF PERFUSION HETEROGENEITY ON INDICATOR EXTRACTION [J].
BRONIKOWSKI, TA ;
LINEHAN, JH ;
DAWSON, CA .
MATHEMATICAL BIOSCIENCES, 1980, 52 (1-2) :27-51
[10]   SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES [J].
BUCKBERG, GD ;
LUCK, JC ;
PAYNE, DB ;
HOFFMAN, JIE ;
ARCHIE, JP ;
FIXLER, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) :598-&