DIAGNOSTIC USEFULNESS OF RENAL SCANNING AFTER ANGIOTENSIN CONVERTING ENZYME-INHIBITORS

被引:38
作者
DAVIDSON, R
WILCOX, CS
机构
[1] DEPT VET AFFAIRS MED CTR,MED SERV 111G,NEPHROL & HYPERTENS SECT,GAINESVILLE,FL 32608
[2] UNIV FLORIDA,COLL MED,DEPT PHARMACOL & THERAPEUT,DIV HYPERTENS & TRANSPLANTAT,GAINESVILLE,FL 32611
[3] UNIV FLORIDA,COLL MED,DEPT MED,GAINESVILLE,FL 32611
[4] UNIV FLORIDA,COLL MED,DEPT MED,DIV GEN MED & NEPHROL,GAINESVILLE,FL 32611
关键词
RENOVASCULAR HYPERTENSION; ANGIOTENSIN CONVERTING ENZYME INHIBITORS; RENAL ARTERY STENOSIS; DIAGNOSTIC IMAGING;
D O I
10.1161/01.HYP.18.3.299
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Radioisotopic renal scanning after angiotensin converting enzyme inhibition (ACEI) has proven to be an exciting area for research. The biologic activity of markers such as DTPA and hippuran, when combined with the physiological effects of ACEI, may provide noninvasive methods of diagnosing both renal artery stenosis and renovascular hypertension. Recent investigators have demonstrated that the sensitivities and specificities of these tests may vary widely; these differences are probably due to variations in study design, patient population, diagnostic criteria, and outcome measurements. We have reviewed these studies and discuss these possible sources of variation and their impact on the clinical usefulness of these diagnostic tests, especially in relation to the prevalence of disease in the population. Current results suggest that the post-ACEI DTPA scan is relatively accurate in the diagnosis of renal artery stenosis, with sensitivity generally greater than 90% and specificity around 95%. However, the best results in predicting the response to angioplasty or surgery in patients with renal artery stenosis have been with the use of post-ACEI hippuran in combination with furosemide (sensitivity, 96%; specificity, 95%). With confirmation of these findings and continued investigation, it is expected that accurate noninvasive tests will be available for widespread clinical use in the near future.
引用
收藏
页码:299 / 303
页数:5
相关论文
共 18 条
[1]  
[Anonymous], 1987, Arch Intern Med, V147, P820
[2]  
BECH K, 1975, ACTA MED SCAND, V197, P65
[3]  
DONDI M, 1989, J NUCL MED, V30, P615
[4]   COST-EFFECTIVENESS IN THE DETECTION OF RENAL-ARTERY STENOSIS [J].
ENGLAND, WL ;
GRIM, CE ;
WEINBERGER, MH ;
ROBERTS, SD .
JOURNAL OF GENERAL INTERNAL MEDICINE, 1988, 3 (04) :344-350
[5]   FUROSEMIDE-131I-HIPPURAN RENOGRAPHY AFTER ANGIOTENSIN-CONVERTING ENZYME-INHIBITION FOR THE DIAGNOSIS OF RENOVASCULAR HYPERTENSION [J].
ERBSLOHMOLLER, B ;
DUMAS, A ;
ROTH, D ;
SFAKIANAKIS, GN ;
BOURGOIGNIE, JJ .
AMERICAN JOURNAL OF MEDICINE, 1991, 90 (01) :23-29
[6]   RENAL SCINTIGRAPHIC CAPTOPRIL TEST IN THE DIAGNOSIS OF RENOVASCULAR HYPERTENSION [J].
FOMMEI, E ;
GHIONE, S ;
PALLA, L ;
MOSCA, F ;
FERRARI, M ;
PALOMBO, C ;
GIACONI, S ;
GAZZETTI, P ;
DONATO, L .
HYPERTENSION, 1987, 10 (02) :212-220
[7]   RENOVASCULAR HYPERTENSION IDENTIFIED BY CAPTOPRIL-INDUCED CHANGES IN THE RENOGRAM [J].
GEYSKES, GG ;
OEI, HY ;
PUYLAERT, CBAJ ;
MEES, EJD .
HYPERTENSION, 1987, 9 (05) :451-458
[8]   SENSITIVITY AND SPECIFICITY OF SCREENING-TESTS FOR RENAL VASCULAR HYPERTENSION [J].
GRIM, CE ;
LUFT, FC ;
WEINBERGER, MH ;
GRIM, CM .
ANNALS OF INTERNAL MEDICINE, 1979, 91 (04) :617-622
[9]   CAPTOPRIL RENOGRAPHY IN THE DIAGNOSIS OF RENAL-ARTERY STENOSIS - ACCURACY AND LIMITATIONS [J].
MANN, SJ ;
PICKERING, TG ;
SOS, TA ;
UZZO, RG ;
SARKAR, S ;
FRIEND, K ;
RACKSON, ME ;
LARAGH, JH .
AMERICAN JOURNAL OF MEDICINE, 1991, 90 (01) :30-40
[10]  
MCGRATH BP, 1983, AUSTR NZ J MED, V11, P359