USE OF THERAPEUTIC ULTRASOUND IN PERCUTANEOUS CORONARY ANGIOPLASTY - EXPERIMENTAL IN-VITRO STUDIES AND INITIAL CLINICAL-EXPERIENCE

被引:51
作者
SIEGEL, RJ
GUNN, J
AHSAN, A
FISHBEIN, MC
BOWES, RJ
OAKLEY, D
WALES, C
STEFFEN, W
CAMPBELL, S
NITA, H
MILLS, T
SILVERTON, P
MYLER, RK
CUMBERLAND, DC
机构
[1] NO GEN HOSP,SHEFFIELD,S YORKSHIRE,ENGLAND
[2] SAN FRANCISCO HEART INST,DALY CITY,CA
关键词
ATHEROSCLEROSIS; ULTRASOUND; ANGIOPLASTY;
D O I
10.1161/01.CIR.89.4.1587
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Previous studies have shown the feasibility of peripheral arterial ultrasound angioplasty. Methods and Results In this report, we describe the use of percutaneous therapeutic ultrasound for coronary angioplasty. In vitro, 11 postmortem, atherosclerotically occluded coronary arteries were obtained to assess catheter-delivered ultrasound for arterial recanalization as well as for assessment of the size of particulate debris. Clinically, coronary ultrasound angioplasty was performed in 19 patients (mean age, 56 years) to assess safety and feasibility for the treatment of obstructive coronary atherosclerosis. Three patients with unstable angina and 16 with exercise-induced myocardial ischemia were treated with a prototype 4.6F coronary catheter ultrasound ablation device with a 1.7-mm diameter ball tip. The ultrasound coronary catheter delivered ultrasound energy at 19.5 kHz, with a power output of 16 to 20 W at the transducer. Energy is delivered in a pulsed mode with a 50% duty cycle of 30 milliseconds. Patients were treated for a mean of 493 seconds (range, 130 to 890) with intracoronary ultrasound ablation. All lesions were treated with adjunctive balloon angioplasty. All 11 postmortem coronary occlusions were recanalized, and 99% of the particulates generated were <10 mu m in diameter. We found that after ultrasound, mean (+/-SD) coronary arterial stenosis fell from 80+/-12% to 60+/-18% (P<.001) and to 26+/-11% (P<.001) after adjunctive balloon angioplasty. Mean pressures required to achieve full balloon inflation were 2.7 atm (range, 1 to 5.5) with a median of 3.0-mm balloon size (2.5 to 3.5). No ultrasound-related complications were identified. Conclusions Intracoronary ultrasound plaque ablation appears to be safe. Our findings suggest that catheter-delivered high-intensity, low-frequency ultrasound may be useful for lesion debulking and enhancing arterial distensibility, allowing balloon dilation at relatively low pressures.
引用
收藏
页码:1587 / 1592
页数:6
相关论文
共 20 条
[1]   DISSOLUTION OF PERIPHERAL ARTERIAL THROMBI BY ULTRASOUND [J].
ARIANI, M ;
FISHBEIN, MC ;
CHAE, JS ;
SADEGHI, H ;
MICHAEL, TAD ;
DUBIN, SB ;
SIEGEL, RJ .
CIRCULATION, 1991, 84 (04) :1680-1688
[2]   PERCUTANEOUS EXCIMER LASER CORONARY ANGIOPLASTY OF LESIONS NOT IDEAL FOR BALLOON ANGIOPLASTY [J].
COOK, SL ;
EIGLER, NL ;
SHEFER, A ;
GOLDENBERG, T ;
FORRESTER, JS ;
LITVACK, F .
CIRCULATION, 1991, 84 (02) :632-643
[3]   HIGH-INTENSITY ULTRASOUND INCREASES DISTENSIBILITY OF CALCIFIC ATHEROSCLEROTIC ARTERIES [J].
DEMER, LL ;
ARIANI, M ;
SIEGEL, RJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (05) :1259-1262
[4]  
DROBINSKI G, 1989, ARCH MAL COEUR VAISS, V82, P377
[5]   CORONARY-ARTERY VASOCONSTRICTION ROUTINELY OCCURS AFTER PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY - A QUANTITATIVE ARTERIOGRAPHIC ANALYSIS [J].
FISCHELL, TA ;
DERBY, G ;
TSE, TM ;
STADIUS, ML .
CIRCULATION, 1988, 78 (06) :1323-1334
[6]   ULTRASONIC ENERGY - EFFECTS ON VASCULAR FUNCTION AND INTEGRITY [J].
FISCHELL, TA ;
ABBAS, MA ;
GRANT, GW ;
SIEGEL, RJ .
CIRCULATION, 1991, 84 (04) :1783-1795
[7]   EFFECT OF LESION CHARACTERISTICS ON OUTCOME OF DIRECTIONAL CORONARY ATHERECTOMY [J].
HINOHARA, T ;
ROWE, MH ;
ROBERTSON, GC ;
SELMON, MR ;
BRADEN, L ;
LEGGETT, JH ;
VETTER, JW ;
SIMPSON, JB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (05) :1112-1120
[8]   ULTRASONIC CLOT DISRUPTION - AN INVITRO STUDY [J].
HONG, AS ;
CHAE, JS ;
DUBIN, SB ;
LEE, S ;
FISHBEIN, MC ;
SIEGEL, RJ .
AMERICAN HEART JOURNAL, 1990, 120 (02) :418-422
[9]  
MONTEVERDE C, 1991, CIRCULATION S2, V84, P69
[10]   EXPERIMENTAL ULTRASONIC ANGIOPLASTY - DISRUPTION OF ATHEROSCLEROTIC PLAQUES AND THROMBI INVITRO AND ARTERIAL RECANALIZATION INVIVO [J].
ROSENSCHEIN, U ;
BERNSTEIN, JJ ;
DISEGNI, E ;
KAPLINSKY, E ;
BERNHEIM, J ;
ROZENZSAJN, LA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (03) :711-717