THE PREDICTIVE PERFORMANCE OF A SYSTEM MODEL FOR ENFLURANE CLOSED-CIRCUIT INHALATIONAL ANESTHESIA

被引:7
作者
LEROU, JGC [1 ]
VERMEULEN, PM [1 ]
DIRKSEN, R [1 ]
BOOIJ, LHDJ [1 ]
BORM, GF [1 ]
机构
[1] CATHOLIC UNIV NIJMEGEN,DEPT MED STAT,6500 HB NIJMEGEN,NETHERLANDS
关键词
ANESTHETICS; VOLATILE; ENFLURANE; ANESTHETIC TECHNIQUES; CLOSED CIRCUIT; BIOTRANSFORMATION (DRUG); COMPUTER; MODELS; SIMULATION; EQUIPMENT; CIRCUITS; CLOSED; MEASUREMENT TECHNIQUES; MASS SPECTROMETRY; PHARMACOKINETICS; DISTRIBUTION; UPTAKE;
D O I
10.1097/00000542-199311000-00010
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Previously, the authors described a system model for closed-circuit inhalational anesthesia, and demonstrated close agreement between end-tidal isoflurane concentrations measured in their clinical study and those predicted by the model. The predictive performance of their model has not, however, been tested for anesthetics featuring nonpulmonary elimination (NPE). Methods. The authors quantified the predictive performance of two versions (A and C) of the model in 50 patients by comparing the predicted and the measured alveolar concentration-time profiles after bolus injections of liquid enflurane into the expiratory limb of the closed system. Version A did not incorporate NPE, but version C emulated NPE by adopting the irreversible toss of a fraction of the enflurane present in the arterial hepatic blood flow (0.131, derived from a mass balance study performed by others). For each concentration measured by mass spectrometry, the authors used computer simulations of version A and C to calculate a predicted concentration for both versions. For each patient, the authors calculated the bias (indicating systematic over- or underprediction) and the scatter of the prediction errors (indicating typical error size). Results: The authors administered a total of 379 ml of liquid enflurane via 466 injections. A total of 18,432 alveolar concentrations (one per 10-s period; average concentration = 0.96 vol%) were measured. The bias and the scatter, both given as mean (and SD), were 10.0 (1 3. 1)% and 11.8 (3.9)% for version A and -0.8 (11.4)% and 11.4 (2.8)% for C. The bias for version C was closer to zero; the scatters were similar. Conclusions: Version C incorporating NPE performs better than version A. The accuracy that was obtained should encourage the use of version C for clinical, teaching, research, economic, and ecologic purposes.
引用
收藏
页码:932 / 942
页数:11
相关论文
共 38 条
[1]   A NONLINEAR MODEL FOR UPTAKE AND DISTRIBUTION OF HALOTHANE IN MAN [J].
ASHMAN, MN ;
BLESSER, WB ;
EPSTEIN, RM .
ANESTHESIOLOGY, 1970, 33 (04) :419-&
[2]   RELATIONSHIP OF CONCENTRATIONS OF HALOTHANE AND ENFLURANE TO THEIR METABOLISM AND ELIMINATION IN MAN [J].
CAHALAN, MK ;
JOHNSON, BH ;
EGER, EI .
ANESTHESIOLOGY, 1981, 54 (01) :3-8
[3]   A NON-INVASIVE INVIVO METHOD OF ASSESSING THE KINETICS OF HALOTHANE METABOLISM IN HUMANS [J].
CAHALAN, MK ;
JOHNSON, BH ;
EGER, EI ;
SHEINER, LB ;
RICHARDSON, CA ;
VARNER, JK ;
SEVERINGHAUS, JW .
ANESTHESIOLOGY, 1982, 57 (04) :298-302
[4]  
CALVERLEY RK, 1978, ANESTH ANALG, V57, P619
[5]   THE EXTENT OF METABOLISM OF INHALED ANESTHETICS IN HUMANS [J].
CARPENTER, RL ;
EGER, EI ;
JOHNSON, BH ;
UNADKAT, JD ;
SHEINER, LB .
ANESTHESIOLOGY, 1986, 65 (02) :201-205
[6]  
CARPENTER RL, 1987, ANESTH ANALG, V66, P1
[7]   BIOTRANSFORMATION OF ETHRANE IN MAN [J].
CHASE, RE ;
HOLADAY, DA ;
FISEROVA.V ;
SAIDMAN, LJ ;
MACK, FE .
ANESTHESIOLOGY, 1971, 35 (03) :262-&
[8]   GASEOUS HOMEOSTASIS AND THE CIRCLE SYSTEM - DESCRIPTION OF A MODEL [J].
CONWAY, CM .
BRITISH JOURNAL OF ANAESTHESIA, 1986, 58 (03) :330-336
[9]   DIGITAL-COMPUTER PREDICTION OF OPTIMAL ANESTHETIC INSPIRED CONCENTRATION [J].
COWLES, AL ;
BORGSTEDT, HH ;
GILLIES, AJ .
BRITISH JOURNAL OF ANAESTHESIA, 1972, 44 (05) :420-+
[10]   TISSUE WEIGHTS AND RATES OF BLOOD FLOW IN MAN FOR PREDICTION OF ANESTHETIC UPTAKE AND DISTRIBUTION [J].
COWLES, AL ;
BORGSTEDT, HH ;
GILLIES, AJ .
ANESTHESIOLOGY, 1971, 35 (05) :523-+