INTEGRATED FIA HPLC METHOD FOR PRECONCENTRATION AND DETERMINATION OF TRANSITION-METAL IONS

被引:20
作者
RICHTER, P
FERNANDEZROMERO, JM
DECASTRO, MDL
VALCARCEL, M
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,E-14004 CORDOBA,SPAIN
[2] UNIV CHILE,FAC SCI,DEPT CHEM,SANTIAGO,CHILE
关键词
COLUMN LIQUID CHROMATOGRAPHY; FLOW INJECTION ANALYSIS; COMBINED METHODS; TRANSITION METAL IONS; AQUEOUS SAMPLES;
D O I
10.1007/BF02290233
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An automatic method based on the combination of a flow injection (FI) manifold with a liquid chromatograph has been developed for the enrichment and determination of transition metal ions in water samples. Alternatively, the FI configuration can be used as a screening system for the determination of the total concentration of heavy metals. Two-parameter expressions for calibration graphs involving preconcentration time and concentration of the analytes were established for both the FIA and the integrated FIA/HPLC methods. The preconcentration time depends on the concentration level of the analytes in the samples. The method is linear in the range 2-200 ng/ml, with r.s.d. values between 1.5 and 5.0. It has been applied to the determination of copper, lead, zinc, nickel, cobalt, cadmium and manganese in synthetic water samples.
引用
收藏
页码:445 / 449
页数:5
相关论文
共 16 条
[1]   TRACE ENRICHMENT METHODS FOR THE DETERMINATION OF METAL-IONS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .2. [J].
CASSIDY, RM ;
ELCHUK, S .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1981, 19 (10) :503-507
[2]  
CASSIDY RM, 1986, REACTION DETECTION L, P129
[3]  
DECASTRO MDL, 1991, J CHROMATOGR SCI, V29, P15
[4]  
HADDAD PR, 1990, J CHROMATOGR LIBRARY, V46
[5]  
HADDAD PR, 1990, J CHROMATOGR LIBR, V46, P401
[6]   FLUORIMETRIC DETERMINATION OF AFLATOXINS IN FOODSTUFFS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLOW-INJECTION ANALYSIS [J].
LAZARO, F ;
DECASTRO, MDL ;
VALCARCEL, M .
JOURNAL OF CHROMATOGRAPHY, 1988, 448 (01) :173-181
[7]  
Lingeman H., 1990, DETECTION ORIENTED D
[8]   ALTERNATIVE USE OF FLOW-INJECTION ANALYSIS AND THE COMBINATION OF LIQUID-CHROMATOGRAPHY AND FLOW-INJECTION ANALYSIS FOR THE DETERMINATION OF TOTAL AND INDIVIDUAL BILE-ACID CONCENTRATIONS IN SERUM [J].
MEMBIELA, A ;
LAZARO, F ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICA CHIMICA ACTA, 1991, 249 (02) :461-467
[9]   COMBINATION OF FLOW-INJECTION ANALYSIS WITH FLAME ATOMIC-ABSORPTION SPECTROPHOTOMETRY - DETERMINATION OF TRACE AMOUNTS OF HEAVY-METALS IN POLLUTED SEAWATER [J].
OLSEN, S ;
PESSENDA, LCR ;
RUZICKA, J ;
HANSEN, EH .
ANALYST, 1983, 108 (1289) :905-917
[10]   PRE-CONCENTRATION EFFICIENCY OF CHELEX-100 RESIN FOR HEAVY-METALS IN SEAWATER .1. EFFECTS OF PH AND SALTS ON THE DISTRIBUTION RATIOS OF HEAVY-METALS [J].
PAI, SC ;
WHUNG, PY ;
LAI, RL .
ANALYTICA CHIMICA ACTA, 1988, 211 (1-2) :257-270