SELECTIVE CONTINUOUS FLOW-STOPPED FLOW-CONTINUOUS FLOW DETERMINATION OF SULFITE IN WHITE WINES USING IMMOBILIZED SULFITE OXIDASE ON A ROTATING REACTOR

被引:10
作者
REZENDE, MO
MOTTOLA, HA
机构
[1] OKLAHOMA STATE UNIV,DEPT CHEM,STILLWATER,OK 74078
[2] UNIV SAO PAULO,DEPT QUIM & FIS MOLEC,BR-13560970 SAO CARLOS,SP,BRAZIL
关键词
SULFITE DETERMINATION; WHITE WINES; CONTINUOUS FLOW-STOPPED FLOW PROCESSING; IMMOBILIZED SULFITE OXIDASE;
D O I
10.1039/an9941902093
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The sulfite ion in white wines has been selectively determined using the sulfite oxidase [EC 1.8.3.1] catalysis of sulfite oxidation in the presence of hexacyanoferrate(III) as the electron acceptor. The hexacyanoferrate(II) produced was detected amperometrically at a stationary Pt ring electrode (pH = 7.50; applied potential, +0.380 V versus Ag-AgCl: 3.0 mol l(-1) NaCl). Ascorbic acid, the most serious interferent in the determination was eliminated before detection by passing the sample through a column with immobilized ascorbate oxidase [EC 1.10.3.3]. Application of the method of standard additions is also possible without the elimination of ascorbate. An unsegmented continuous flow stream passes the sample/reagent(s) through the column and directs it/them to the cell where contact is made with immobilized sulfite oxidase on a rotating disc. This disc is located at the bottom of the cell, while the Pt electrode is located at the top of the cell. The results of determinations using the proposed method correlate well with those of determinations conducted using the official Association of Analytical Chemists (AOAC) modified Monier-Williams method.
引用
收藏
页码:2093 / 2096
页数:4
相关论文
共 16 条
[1]  
Amerine M. A., 1980, TECHNOLOGY WINE MAKI
[2]   COMPARATIVE-STUDIES ON DATA-COLLECTION AND DATA TREATMENT IN KINETIC-BASED DETERMINATIONS WITH 2 ROTATING BIOREACTOR AMPEROMETRIC DETECTION SYSTEMS [J].
BAEZA, JJB ;
MATSUMOTO, K ;
MOTTOLA, HA .
ANALYTICA CHIMICA ACTA, 1993, 283 (02) :785-793
[3]  
BAEZA JJB, 1993, QUIM ANAL, V12, P12
[4]  
Borgstrom G., 1969, PRINCIPLES FOOD SCI
[5]  
COHEN HJ, 1971, J BIOL CHEM, V246, P359
[6]  
HELRICH K, 1990, OFFICIAL METHODS ANA, P1158
[7]  
LEUBOLT R, 1993, J CHROMATOGR, V640, P636
[8]  
LICHINE A, 1981, NEW ENCY WINES SPIRI
[9]   CONTINUOUS-FLOW SENSOR STRATEGY COMPRISING A ROTATING BIOREACTOR AND A STATIONARY RING AMPEROMETRIC DETECTOR [J].
MATSUMOTO, K ;
BAEZA, JJB ;
MOTTOLA, HA .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :636-639
[10]   SIMULTANEOUS KINETIC-BASED DETERMINATION OF FRUCTOSE AND ASCORBATE WITH A ROTATING BIOREACTOR AND AMPEROMETRIC DETECTION - APPLICATION TO THE ANALYSIS OF FOOD SAMPLES [J].
MATSUMOTO, K ;
BAEZA, JJB ;
MOTTOLA, HA .
ANALYTICAL CHEMISTRY, 1993, 65 (13) :1658-1661