DETERMINATION OF AMOXICILLIN IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION AFTER ONLINE OXIDATION

被引:30
作者
MASCHER, H
KIKUTA, C
机构
[1] Pharm-Analyt Lab. GmbH, Wienerstrasse 37, P.O. Box 4
来源
JOURNAL OF CHROMATOGRAPHY | 1990年 / 506卷
关键词
D O I
10.1016/S0021-9673(01)91597-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simplified high-performance liquid chromatographic method for the determination of amoxicillin in plasma is described. Specific and sensitive fluorescence detection was achieved by on-line post-column electrochemical oxidation, using an electrochemical detector. Owing to the high specificity of the detection system, deproteinized plasma samples could be injected directly without prior treatment. This method permits a very fast and reproducible determination of amoxicillin in plasma on a routine basis at levels, down to 50 ng/ml. The absolute detection limit is about 10 pg injected. © 1990.
引用
收藏
页码:417 / 421
页数:5
相关论文
共 9 条
[1]   DETERMINATION OF AMOXICILLIN IN BODY-FLUIDS BY REVERSED-PHASE LIQUID-CHROMATOGRAPHY COUPLED WITH A POST-COLUMN DERIVATIZATION PROCEDURE [J].
CARLQVIST, J ;
WESTERLUND, D .
JOURNAL OF CHROMATOGRAPHY, 1979, 164 (03) :373-381
[2]   AUTOMATED-DETERMINATION OF AMOXYCILLIN IN BIOLOGICAL-FLUIDS BY COLUMN SWITCHING IN ION-PAIR REVERSED-PHASE LIQUID-CHROMATOGRAPHIC SYSTEMS WITH POST-COLUMN DERIVATIZATION [J].
CARLQVIST, J ;
WESTERLUND, D .
JOURNAL OF CHROMATOGRAPHY, 1985, 344 (NOV) :285-296
[3]   ASSAY OF AMOXICILLIN AND CLAVULANIC ACID, THE COMPONENTS OF AUGMENTIN, IN BIOLOGICAL-FLUIDS WITH HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
FOULSTONE, M ;
READING, C .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1982, 22 (05) :753-762
[4]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY OF AMPICILLIN, AMOXICILLIN AND CICLACILLIN IN SERUM AND URINE USING A PRE-COLUMN REACTION WITH 1,2,4-TRIAZOLE AND MERCURY(II) CHLORIDE [J].
HAGINAKA, J ;
WAKAI, J .
ANALYST, 1985, 110 (11) :1277-1281
[5]   LIQUID-CHROMATOGRAPHIC DETERMINATION OF AMOXICILLIN AND ITS METABOLITES IN HUMAN-URINE BY POSTCOLUMN DEGRADATION WITH SODIUM-HYPOCHLORITE [J].
HAGINAKA, J ;
WAKAI, J .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 413 :219-226
[6]   HIGH-PRESSURE LIQUID-CHROMATOGRAPHIC DETERMINATION OF AMOXICILLIN IN URINE [J].
LEE, TL ;
DARCONTE, L ;
BROOKS, MA .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1979, 68 (04) :454-458
[7]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF AMOXICILLIN IN HUMAN-PLASMA USING A BONDED-PHASE EXTRACTION [J].
LEE, TL ;
BROOKS, MA .
JOURNAL OF CHROMATOGRAPHY, 1984, 306 (MAR) :429-435
[8]   DETERMINATION OF AMPICILLIN, AMOXICILLIN, CEPHALEXIN, AND CEPHRADINE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING FLUOROMETRIC DETECTION [J].
MIYAZAKI, K ;
OHTANI, K ;
SUNADA, K ;
ARITA, T .
JOURNAL OF CHROMATOGRAPHY, 1983, 276 (02) :478-482
[9]   RAPID-DETERMINATION OF AMOXYCILLIN (CLAMOXYL) AND AMPICILLIN (PENBRITIN) IN BODY-FLUIDS OF MANY BY MEANS OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
VREE, TB ;
HEKSTER, YA ;
BAARS, AM ;
VANDERKLEIJN, E .
JOURNAL OF CHROMATOGRAPHY, 1978, 145 (03) :496-501