INTRAOCULAR-PRESSURE MEASUREMENT AFTER PENETRATING KERATOPLASTY - MINIFIED GOLDMANN APPLANATION TONOMETER, PNEUMATONOMETER, AND TONO-PEN VERSUS MANOMETRY

被引:26
作者
MENAGE, MJ [1 ]
KAUFMAN, PL [1 ]
CROFT, MA [1 ]
LANDAY, SP [1 ]
机构
[1] UNIV WISCONSIN,CTR CLIN SCI,DEPT OPHTHALMOL & VISUAL SCI,MADISON,WI 53792
关键词
D O I
10.1136/bjo.78.9.671
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The accuracy of intraocular pressure measurement with the minified Goldmann applanation tonometer, the pneumatonometer, and the Tone-Pen tonometer were compared in post-mortem human eyes which had undergone penetrating keratoplasty. Enucleated postmortem human eyes underwent same sized (7.75 mm) or 0.5 mm oversized (8.25 mm) autologous penetrating keratoplasty. Intraocular pressure was then set and measured manometrically while being determined successively with each tonometer over the range of 0-65 mm Hg. Linear regression analysis comparing tonometric and manometric readings showed: (1) minified Goldmann applanation tonometer - slope 0.985 and 0.944, intercept 1.64 and 2.55 mm Hg, correlation coefficient 0.99 and 0.99 in same sized and oversized grafted eyes respectively; (2) pneumatonometer - slope 1.008 and 0.990, intercept 3.37 and 3.69 mm Hg, correlation coefficient 0.99 and 0.98; (3) Tono-Pen-slope 1.061 and 1.002, intercept 5.01 and 4.06 mm Hg, correlation coefficient 0.97 and 0.98. We concluded that the minified Goldmann applanation tonometer is as accurate or more accurate than the pneumatonometer and the Tone-Pen in postmortem post-keratoplasty human eyes, and may be an economical, convenient alternative to the latter two instruments in clinical practice.
引用
收藏
页码:671 / 676
页数:6
相关论文
共 33 条
[1]  
BARANY EH, 1964, INVEST OPHTH VISUAL, V3, P135
[2]   THE TONO-PEN - A MANOMETRIC AND CLINICAL-STUDY [J].
BOOTHE, WA ;
LEE, DA ;
PANEK, WC ;
PETTIT, TH .
ARCHIVES OF OPHTHALMOLOGY, 1988, 106 (09) :1214-1217
[3]  
FRENKEL REP, 1988, ARCH OPHTHALMOL-CHIC, V106, P750
[4]   TONO-PEN TONOMETRY IN NORMAL AND IN POSTKERATOPLASTY EYES [J].
GEYER, O ;
MAYRON, Y ;
LOEWENSTEIN, A ;
NEUDORFER, M ;
ROTHKOFF, L ;
LAZAR, M .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1992, 76 (09) :538-540
[5]  
GOLDMANN H, 1957, 2ND J MAC JR F C GLA, P186
[6]  
HAHNENBERGER RW, 1976, ACTA OPHTHALMOL, V54, P311
[7]   OVERSIZED DONOR GRAFTS IN PENETRATING KERATOPLASTY - A RANDOMIZED TRIAL [J].
HEIDEMANN, DG ;
SUGAR, A ;
MEYER, RF ;
MUSCH, DC .
ARCHIVES OF OPHTHALMOLOGY, 1985, 103 (12) :1807-1811
[8]  
HESSEMER V, 1988, AM J OPHTHALMOL, V105, P1678
[9]   GOLDMANN APPLANATION TONOMETRY IN PATIENTS WITH REGULAR CORNEAL ASTIGMATISM [J].
HOLLADAY, JT ;
ALLISON, ME ;
PRAGER, TC .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1983, 96 (01) :90-93
[10]   INTRAOCULAR PRESSURE FOLLOWING PENETRATING KERATOPLASTY [J].
IRVINE, AR ;
KAUFMAN, HE .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1969, 68 (05) :835-&