Purpose: To investigate the effect of posterior chamber intraocular lens (PC I0L) size and construction on the capsular bag in human cadaver eyes. Methods: Studies were done at two timeframes: (1) short term (prospective)-the effect of 12 different IOLs on the capsular bag configuration after experimental implantation; and (2) long term-(retrospective) analysis of eyes with PC IOLs obtained postmortem. Results: The short-term study showed the maximal diameter of the capsular bag to be 11.0 mm for IOLs with total diameter of 12.0 mm and 11.5 mm for 13.5- to 14.0-mm IOLs, Longer IOLs caused more ovaling of the bag with stress lines (striae) on the posterior capsule. Secondary processes such as proliferation of epithelial cells (Soemmering ring) and capsular fibrosis caused the capsular bag to resume a more circular shape with irregular contour. The area of contact between the I0L loops and the capsular equator was significantly lower in eyes with radial tears and IOLs with the J-loop design compared with the C-loop design, In both the short- and long-term groups, maximal capsular diameter did not exceed 12.0 mm. Conclusions: The results of this study suggest that using the capsulorrhexis technique, a 12.0-mm total diameter IOL is sufficient to provide stable capsular fixation.
引用
收藏
页码:1151 / 1157
页数:7
相关论文
共 14 条
[1]  
APPLE DJ, 1990, OPHTHALMOLOGY, V97, P810
[2]   SIDE-VIEW ANALYSIS OF THE LENS .1. THE CRYSTALLINE LENS AND THE EVACUATED BAG [J].
ASSIA, EI ;
APPLE, DJ .
ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (01) :89-93
[3]   SIDE-VIEW ANALYSIS OF THE LENS .2. POSITIONING OF INTRAOCULAR LENSES [J].
ASSIA, EI ;
APPLE, DJ .
ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (01) :94-98
[4]   THE ELASTIC PROPERTIES OF THE LENS CAPSULE IN CAPSULORHEXIS [J].
ASSIA, EI ;
APPLE, DJ ;
TSAI, JC ;
LIM, ES .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1991, 111 (05) :628-632
[5]  
Assia EI, 1991, OPHTHALMOL CLIN N AM, V4, P251
[6]  
Galand A, 1984, AM INTRAOCULAR IMPLA, V10, P475
[7]  
HANSEN SO, 1988, OPHTHALMOLOGY, V95, P344
[8]   PROSPECTIVE EXPERIMENTAL-STUDY OF FACTORS RELATED TO POSTERIOR CHAMBER INTRAOCULAR-LENS DECENTRATION [J].
LEGLER, UFC ;
ASSIA, EI ;
CASTANEDA, VE ;
HOGGATT, JP ;
APPLE, DJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (05) :449-455
[9]   THE RATIO OF LENS THICKNESS TO AXIAL LENGTH FOR BIOMETRIC STANDARDIZATION IN ANGLE-CLOSURE GLAUCOMA [J].
MARKOWITZ, SN ;
MORIN, JD .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1985, 99 (04) :400-402
[10]  
Ohmi S, 1992, Nippon Ganka Gakkai Zasshi, V96, P1093