BIOARGOS - A FULLY AUTOMATED BLOOD CULTURE SYSTEM

被引:9
作者
COURCOL, RJ
DUHAMEL, M
DECOSTER, A
LEMAIRE, VM
RASTORGOUEFF, ML
OCHIN, D
MARTIN, GR
机构
[1] ST ANTOINE HOSP,MICROBIOL LAB,F-59019 LILLE,FRANCE
[2] SANOFI DIAGNOST PASTEUR,F-92430 MARNES COQUETTE,FRANCE
关键词
D O I
10.1128/JCM.30.8.1995-1998.1992
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
BioArgos (Sanofi Diagnostics Pasteur, Marnes-la-Coquette, France) is a fully automated blood culture system that detects carbon dioxide production by infrared spectroscopy through a glass bottle. This hands-off system was compared with the BACTEC NR-660 system (Becton Dickinson Diagnostic Instrument Systems, Towson, Md.). A total of 336 microorganisms belonging to 74 taxa were tested in simulated blood cultures by both systems. Experimental data showed no significant differences between the two systems. The inclusive detection times (+/- the standard deviations) were 33.2 +/- 28.7 and 35.0 +/- 30.6 h with BioArgos and BACTEC, respectively. Anaerobes were detected earlier with BioArgos, whereas detection of some organisms that need oxygen to grow was slightly delayed. In conclusion, BioArgos is as reliable and accurate as BACTEC NR-660 and shows better practicability owing to noninvasive detection, reduction of vial manipulation, and absence of daily maintenance.
引用
收藏
页码:1995 / 1998
页数:4
相关论文
共 11 条
[1]   BIOLUMINESCENT MEASUREMENT OF ATP FOR THE RAPID DETECTION OF POSITIVE BLOOD CULTURES [J].
BECKERS, B ;
LANG, HRM .
NATURWISSENSCHAFTEN, 1982, 69 (03) :145-146
[2]   ROUTINE EVALUATION OF THE NONRADIOMETRIC BACTEC NR-660 SYSTEM [J].
COURCOL, RJ ;
FRUCHART, A ;
ROUSSELDELVALLEZ, M ;
MARTIN, GR .
JOURNAL OF CLINICAL MICROBIOLOGY, 1986, 24 (01) :26-29
[3]   AUTOMATED RADIOMETRIC DETECTION OF BACTERIA IN 2,967 BLOOD CULTURES [J].
DEBLANC, HJ ;
DELAND, F ;
WAGNER, HN .
APPLIED MICROBIOLOGY, 1971, 22 (05) :846-&
[4]   EARLY DETECTION OF BACTERIAL GROWTH WITH CARBON-14-LABELED GLUCOSE [J].
DELAND, FH ;
WAGNER, HN .
RADIOLOGY, 1969, 92 (01) :154-&
[5]   RAPID DIAGNOSIS OF BACTEREMIA [J].
FINEGOLD, SM ;
WHITE, ML ;
ZIMENT, I ;
WINN, WR .
APPLIED MICROBIOLOGY, 1969, 18 (03) :458-&
[6]   SODIUM POLYANETHOL SULFONATE SENSITIVITY OF ANAEROBIC COCCI [J].
GRAVES, MH ;
MORELLO, JA ;
KOCKA, FE .
APPLIED MICROBIOLOGY, 1974, 27 (06) :1131-1133
[7]  
MANTZ JM, 1981, NOUV PRESSE MED, V30, P2489
[8]  
OCHIN D, 1989, 4TH EUR C CLIN MICR
[9]  
ROT P, 1990, B EPIDEMIOLOGIQUE HE, V33, P142
[10]   BACT/ALERT - AN AUTOMATED COLORIMETRIC MICROBIAL DETECTION SYSTEM [J].
THORPE, TC ;
WILSON, ML ;
TURNER, JE ;
DIGUISEPPI, JL ;
WILLERT, M ;
MIRRETT, S ;
RELLER, LB .
JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (07) :1608-1612