CORRELATION BETWEEN FLUORESCEIN FLOWMETRY AND LASER DOPPLER FLOWMETRY - A STUDY IN THE INTESTINE (ILEOANAL POUCH) IN MAN

被引:11
作者
PERBECK, L
LINDQUIST, K
PROANO, E
LILJEQVIST, L
机构
[1] Dept. of Surgery, Huddinge University Hospital, Karolinska Institute, Huddinge
关键词
Fluorescein flowmetry; Ileoanal pouch in man; Intestinal capillary blood flow; Laser Doppler flowmetry;
D O I
10.3109/00365529009095524
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
A study was undertaken to compare two new methods of capillary blood flow measurement, namely fluorescein flowmetry (FF) and laser Doppler flowmetry (LDF). The blood flow was measured in a pelvic pouch during its construction and in the completed ileoanal anastomosis in 12 patients. There was a high correlation between the two methods (correlation coefficient, 0.78) (p <0.01) when the blood flow was measured in the pelvic pouch. The correlation coefficient between the two methods for the difference between the blood flow in the pelvic pouch at the site of the planned anastomosis when the pouch resided in the abdomen and that in the completed ileoanal anastomosis was r = 0.99 (n = 12, p< 0.001); the reduction amounted to 25 % as measured by FF and 27 % as measured by LDF (n = 12, p < 0.01). All ileoanal anastomoses healed perfectly, the lowest FF and LDF values being 0.004 density units/sec and 0.3 V, respectively. The results indicate that either method can be considered for measuring capillary blood flow. © 1990 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted.
引用
收藏
页码:520 / 524
页数:5
相关论文
共 8 条
[1]   ASSESSMENT OF BLOOD-FLOW IN THE SMALL-INTESTINE WITH LASER DOPPLER FLOWMETRY [J].
AHN, H ;
LINDHAGEN, J ;
NILSSON, GE ;
OBERG, PA ;
LUNDGREN, O .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1986, 21 (07) :863-870
[2]   EVALUATION OF LASER DOPPLER FLOWMETRY IN THE ASSESSMENT OF INTESTINAL BLOOD-FLOW IN CAT [J].
AHN, H ;
LINDHAGEN, J ;
NILSSON, GE ;
SALERUD, EG ;
JODAL, M ;
LUNDGREN, O .
GASTROENTEROLOGY, 1985, 88 (04) :951-957
[3]   TISSUE PENETRATION AND MEASURING DEPTH OF LASER DOPPLER FLOWMETRY IN THE GASTROINTESTINAL APPLICATION [J].
JOHANSSON, K ;
AHN, H ;
LINDHAGEN, J ;
LUNDGREN, O .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1987, 22 (09) :1081-1088
[4]   GASTRIC-MUCOSAL BLOOD-FLOW MEASURED BY LASER-DOPPLER VELOCIMETRY [J].
KIEL, JW ;
RIEDEL, GL ;
DIRESTA, GR ;
SHEPHERD, AP .
AMERICAN JOURNAL OF PHYSIOLOGY, 1985, 249 (04) :G539-G545
[5]   NEW INSTRUMENT FOR CONTINUOUS MEASUREMENT OF TISSUE BLOOD-FLOW BY LIGHT BEATING SPECTROSCOPY [J].
NILSSON, GE ;
TENLAND, T ;
OBERG, PA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (01) :12-19
[6]  
PERBECK L, 1985, CLIN PHYSIOL, V5, P293
[7]  
PERBECK L, 1985, CLIN PHYSIOL, V5, P281
[8]   THE MUCOSAL BLOOD-FLOW IN PELVIC POUCHES IN MAN - A METHODOLOGIC STUDY OF FLUORESCEIN FLOWMETRY [J].
PERBECK, L ;
LINDQUIST, K ;
LILJEQVIST, L .
DISEASES OF THE COLON & RECTUM, 1985, 28 (12) :931-936