QUANTITATIVE AUTORADIOGRAPHIC IMAGING USING GAS-COUNTER TECHNOLOGY

被引:5
作者
BATEMAN, JE
机构
[1] Rutherford Appleton Laboratory, Didcot, Oxfordshire, Chilton
关键词
D O I
10.1002/elps.1150110505
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Gas counters based on the multiwire proportional counter (MWPC) and multistep avalanche (MSA) technologies can combine the functions of imaging and quantitation (or assay) of radioactively labelled electrophoretograms and blots. Submillimeter spatial resolutions combined with good quantitation have been achieved for the most common beta‐emitting radio labels. The current state of development of this technology is reviewed and assessments of the performance of these devices relative to the more traditional systems (X‐ray film and the scintillation counter) presented. Particular attention is paid to the potential of these devices to enhance the productivity of the scanning of blots and the performance of assays. Copyright © 1990 VCH Verlagsgesellschaft mbH
引用
收藏
页码:367 / 375
页数:9
相关论文
共 19 条
[1]   MWPC DEVELOPMENTS AT RUTHERFORD-APPLETON-LABORATORY FOR MEDICAL IMAGING [J].
BATEMAN, JE ;
STEPHENSON, R ;
CONNOLLY, JF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 269 (02) :415-424
[2]   AN IMPROVED MULTISTEP AVALANCHE DETECTOR SYSTEM FOR DIGITAL AUTORADIOGRAPHY [J].
BATEMAN, JE ;
CONNOLLY, JF ;
STEPHENSON, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 264 (2-3) :430-435
[4]   HIGH-SPEED QUANTITATIVE DIGITAL BETA-AUTORADIOGRAPHY USING A MULTISTEP AVALANCHE DETECTOR AND AN APPLE-II MICROCOMPUTER [J].
BATEMAN, JE ;
CONNOLLY, JF ;
STEPHENSON, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 241 (01) :275-289
[5]   COLORIMETRIC-DETECTED DNA SEQUENCING [J].
BECK, S .
ANALYTICAL BIOCHEMISTRY, 1987, 164 (02) :514-520
[6]   THE MULTISTEP CHAMBER AS A HIGH-ACCURACY LOCALIZATION DEVICE FOR BETA-CHROMATOGRAPHY AND SLOW-NEUTRON IMAGING [J].
CHARPAK, G ;
MELCHART, G ;
PETERSEN, G ;
SAULI, F .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (01) :849-851
[7]   MULTISTEP AVALANCHE CHAMBER - NEW HIGH-RATE, HIGH-ACCURACY GASEOUS DETECTOR [J].
CHARPAK, G ;
SAULI, F .
PHYSICS LETTERS B, 1978, 78 (04) :523-528
[8]   A GASEOUS DETECTOR FOR HIGH-ACCURACY AUTORADIOGRAPHY OF RADIOACTIVE COMPOUNDS WITH OPTICAL READOUT OF AVALANCHE POSITIONS [J].
DOMINIK, W ;
ZAGANIDIS, N ;
ASTIER, P ;
CHARPAK, G ;
SANTIARD, JC ;
SAULI, F ;
TRIBOLLET, E ;
GEISSBUHLER, A ;
TOWNSEND, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 278 (03) :779-787
[9]   MORE COMPETITION IN SEQUENCING [J].
FERRIS, S ;
ZROLKA, A .
BIO-TECHNOLOGY, 1988, 6 (03) :323-323
[10]   A SIMPLE ELECTRONIC APPARATUS FOR THE ANALYSIS OF RADIOACTIVELY LABELED GEL ELECTROPHORETOGRAMS [J].
GOULIANOS, K ;
SMITH, KK ;
WHITE, SN .
ANALYTICAL BIOCHEMISTRY, 1980, 103 (01) :64-69