IMPLANTABLE ELECTROCATALYTIC GLUCOSE SENSOR

被引:9
作者
LAGER, W
VONLUCADOU, I
NISCHIK, H
NOWAK, T
PREIDEL, W
RUPRECHT, L
STANZEL, MJ
TEGEDER, V
机构
[1] SIEMENS AG,CORP RES & DEV,ZFE BT EP 13,D-91050 ERLANGEN,GERMANY
[2] UNIV ERLANGEN NURNBERG,INST ZOOL,W-8520 ERLANGEN,GERMANY
[3] FORSCHUNGSZENTRUM UMWELT & GESUNDHEIT,MUNICH,GERMANY
关键词
GLUCOSE SENSOR; ELECTROCATALYTIC GLUCOSE MEASUREMENT; IMPEDANCE METHOD; IN VIVO MEASUREMENT; LONG-TERM STABILITY; IN VIVO CALIBRATION;
D O I
10.1055/s-2007-1001749
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
An electrocatalytic glucose sensor for in vivo application has been developed to determine the glucose level in blood and further to control the insulin dosage in a closed loop system for diabetes therapy. The principle of the electrocatalytic glucose sensor is based on the direct electrochemical oxidation of glucose at a membrane-covered platinum electrode. For a possible clinical application the sensor was built as a catheter. A set of implantations in the vena cava of sheep demonstrated the potential feasibility of the sensor. The sensor values were simultaneously checked by the enzymatic analysis of glucose in blood samples drawn separately from a femoral vein. It was possible to determine the glucose concentration in sheep for more than 130 days with tolerable deviations from glucose reference measurements. The mean error was 2.5 mmol/l. One of the catheters was explanted after 211 days and the histological examination revealed a good biocompatibility of all materials used. In additional experiments, the differences of the glucose concentration in vena cava as well as in the anterior and posterior femoral veins of a sheep were examined during glucose tolerance tests. These experiments verified our method of in vivo calibration of the long-term implantable glucose sensor.
引用
收藏
页码:526 / 530
页数:5
相关论文
共 14 条
[1]   APPLICATION OF CHRONIC INTRAVASCULAR BLOOD-GLUCOSE SENSOR IN DOGS [J].
ARMOUR, JC ;
LUCISANO, JY ;
MCKEAN, BD ;
GOUGH, DA .
DIABETES, 1990, 39 (12) :1519-1526
[2]   ON THE ELECTROCHEMICAL OXIDATION OF GLUCOSE - IDENTIFICATION OF VOLATILE PRODUCTS BY ONLINE MASS-SPECTROSCOPY [J].
BOLZAN, AE ;
IWASITA, T ;
VIELSTICH, W .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1987, 134 (12) :3052-3058
[3]  
DRAKE RF, 1972, PB210662
[4]   DOES PHYSIOLOGICAL BLOOD-GLUCOSE CONTROL REQUIRE AN ADAPTIVE-CONTROL STRATEGY [J].
FISCHER, U ;
SCHENK, W ;
SALZSIEDER, E ;
ALBRECHT, G ;
ABEL, P ;
FREYSE, EJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (08) :575-582
[5]  
FRANETZKI M, 1984, PHARM RES, V6, P237
[6]  
GEBHARDT U, 1983, SIEMENS FORSCH ENTW, V12, P91
[7]  
GINER J, 1972, DESIGN CONSIDERATION, P283
[8]   ELECTROCHEMICAL GLUCOSE OXIDATION ON A PLATINIZED PLATINUM-ELECTRODE IN KREBS-RINGER SOLUTION .2. POTENTIOSTATIC STUDIES [J].
LERNER, H ;
GINER, J ;
SOELDNER, JS ;
COLTON, CK .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1979, 126 (02) :237-242
[9]   USE OF ARTIFICIAL PANCREAS AND PORTABLE INSULIN INFUSION PUMPS IN DIABETES THERAPY - PAST, PRESENT, AND FUTURE [J].
PFEIFFER, EF ;
KERNER, W .
ARTIFICIAL ORGANS, 1985, 9 (02) :129-137
[10]  
PREIDEL W, 1990, Patent No. 4919770