DETERMINATION OF TRACE-ELEMENTS IN FOOD CONTACT POLYMERS BY SEMIQUANTITATIVE INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY - PERFORMANCE EVALUATION USING ALTERNATIVE MULTIELEMENT TECHNIQUES AND IN-HOUSE POLYMER REFERENCE MATERIALS

被引:44
作者
FORDHAM, PJ
GRAMSHAW, JW
CASTLE, L
CREWS, HM
THOMPSON, D
PARRY, SJ
MCCURDY, ED
机构
[1] MAFF,CLS FOOD SCI LAB,NORWICH NR4 7UQ,NORFOLK,ENGLAND
[2] UNIV LONDON IMPERIAL COLL SCI & TECHNOL,CTR ANALYT RES ENVIRONM,ASCOT SL5 7TE,BERKS,ENGLAND
[3] FISONS INSTRUMENTS ELEMENTAL ANAL,WINSFORD CW7 3BX,CHESHIRE,ENGLAND
关键词
INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; MICROWAVE DIGESTION; MULTIELEMENT REFERENCE MATERIALS; FOOD CONTACT POLYMERS; NEUTRON ACTIVATION ANALYSIS; LASER ABLATION;
D O I
10.1039/ja9951000303
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of trace elements in a wide range of polymers intended for food contact use was carried out by inductively coupled plasma mass spectrometry (ICP-MS). Microwave digestion in concentrated nitric and sulfuric acids enabled rapid wet oxidation of all the polymers, to give samples suitable for introduction into the plasma. Semiquantitative multi-element screening of the polymer digests could then be carried out using a single indium internal standard. Limits of detection for the polymers were generally in the order of 1 mg kg(-1). Owing to the paucity of suitable standard reference polymer materials required for validation of the procedures used, a series of in-house reference materials was prepared by incorporating a cocktail of metal stearates into a range of polymer materials via the melt. Levels of elements in these reference materials were established by two reference methods: direct neutron activation analysis (NAA) and a quantitative ICP-MS method. Results fog the two reference methods were encouragingly close to nominal added values and replicate analyses indicated that homogeneity was good. Further analysis of the materials using laser ablation ICP-MS confirmed that the distribution of elements within the polymer matrix was satisfactory. In addition, NAA was carried out On the great majority of the polymer samples as a further aid to validation of the semi-quantitative multi-element ICP-MS method.
引用
收藏
页码:303 / 309
页数:7
相关论文
共 24 条
[1]  
AMARASIRIWARDEN.CJ, 1990, J ANAL ATOM SPECTROM, V5, P457
[2]   DETERMINATION OF METALS IN POLYVINYL-CHLORIDE) BY ATOMIC-ABSORPTION SPECTROMETRY .3. DETERMINATION OF CADMIUM, ANTIMONY AND TIN IN SAMPLES OF POLYVINYL-CHLORIDE) WITH CARBON-BLACK [J].
BELARRA, MA ;
AZOFRA, MC ;
ANZANO, JM ;
CASTILLO, JR .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (04) :591-593
[3]   DETERMINATION OF LEAD AND CADMIUM IN SAMPLES OF POLYVINYL-CHLORIDE) USING ORGANIC-SOLVENTS BY FLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
BELARRA, MA ;
ANZANO, JM ;
CASTILLO, JR .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 334 (02) :118-121
[4]   LASER SOLID SAMPLING FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
DENOYER, ER ;
FREDEEN, KJ ;
HAGER, JW .
ANALYTICAL CHEMISTRY, 1991, 63 (08) :A445-&
[5]   SEMIQUANTITATIVE SURVEY CAPABILITIES OF INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
EKIMOFF, D ;
VANNORSTRAND, AM ;
MOWERS, DA .
APPLIED SPECTROSCOPY, 1989, 43 (07) :1252-1257
[7]  
GRAY AL, 1989, APPLICATIONS ICP MS, P21
[8]   PLASMA SOURCE-MASS SPECTROMETRY [J].
HIEFTJE, GM ;
NORMAN, LA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 118 :519-573
[9]  
KENNEDY GC, 1990, 1989 S P MET POL, P128
[10]   COMPARISON STANDARDS FOR NEUTRON-ACTIVATION ANALYSIS ON A BASE OF PHENOL-FORMALDEHYDE RESIN [J].
KOLOMITSEV, MA ;
AMBARDAN.TS ;
DUNDUA, VY .
JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1974, 20 (02) :549-557