QUANTITATIVE CONCENTRATION MEASUREMENTS OF ATOMIC SODIUM IN AN ATMOSPHERIC HYDROCARBON FLAME WITH ASYNCHRONOUS OPTICAL-SAMPLING

被引:7
作者
FIECHTNER, GJ [1 ]
KING, GB [1 ]
LAURENDEAU, NM [1 ]
机构
[1] PURDUE UNIV,SCH MECH ENGN,FLAME DIAGNOST LAB,W LAFAYETTE,IN 47907
来源
APPLIED OPTICS | 1995年 / 34卷 / 06期
关键词
COMBUSTION; TURBULENCE; SODIUM; PICOSECOND PHENOMENA; MODE-LOCKED LASERS; ABSORPTION; SPECTROSCOPY;
D O I
10.1364/AO.34.001117
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report the development of a pump-probe instrument that uses a high-repetition-rate (82-MHz) picosecond laser. To maximize laser power and to minimize jitter between the pump- and the probe-pulse trains, we choose the asynchronous optical sampling (ASOPS) configuration. Verification of the method is obtained through concentration measurements of atomic sodium in an atmospheric methane-air flame. For the first time to our knowledge, ASOPS measurements are made on a quantitative basis. This is accomplished by calibration of the sodium concentration with atomic absorption spectroscopy. ASOPS measurements are taken at a rate of 155.7 kHZ With only 128 averages, resulting in a corresponding detection limit of 5 x 10(9) cm(-3). The quenching-rate coefficient is obtained in a single measurement with a variation of ASOPS, which we call dual-beam ASOPS. The value of this coefficient is in excellent agreement with literature values for the present flame conditions. Based on our quantitative results for detection of atomic sodium, a detection limit of 2 x 10(17) cm(-3) is predicted for the Q(1) (9) line of A (2) Sigma(+) (v = 0)-X(2)II (v = 0) hydroxyl at 2000 K; Although this value is too large for practical flame studies, a number of improvements that should lower the ASOPS detection limit are suggested.
引用
收藏
页码:1117 / 1126
页数:10
相关论文
共 28 条
[1]  
Alkemade C. T. J., 1982, METAL VAPOURS FLAMES
[2]   SIMULTANEOUS MEASUREMENT OF RAMAN-SCATTERING AND LASER-INDUCED OH FLUORESCENCE IN NONPREMIXED TURBULENT JET FLAMES [J].
BARLOW, RS ;
DIBBLE, RW ;
LUCHT, RP .
OPTICS LETTERS, 1989, 14 (05) :263-265
[3]   CONCENTRATION-MODULATED ABSORPTION-SPECTROSCOPY .2. TEMPORAL VARIATION OF GAIN [J].
BEAMAN, RA ;
DAVIES, AN ;
LANGLEY, AJ ;
JONES, WJ ;
BARAN, J .
CHEMICAL PHYSICS, 1986, 101 (01) :127-132
[4]   TRANSFORM-LIMITED BEHAVIOR FROM THE SYNCHRONOUSLY PUMPED CW DYE-LASER [J].
BLANCHARD, GJ ;
WIRTH, MJ .
OPTICS COMMUNICATIONS, 1985, 53 (06) :394-400
[5]  
CARTER CD, 1990, THESIS PURDUE U W LA
[6]   PUMP PROBE METHOD FOR FAST ANALYSIS OF VISIBLE SPECTRAL SIGNATURES UTILIZING ASYNCHRONOUS OPTICAL-SAMPLING [J].
ELZINGA, PA ;
KNEISLER, RJ ;
LYTLE, FE ;
JIANG, Y ;
KING, GB ;
LAURENDEAU, NM .
APPLIED OPTICS, 1987, 26 (19) :4303-4309
[7]  
ELZINGA PA, 1986, THESIS PURDUE U W LA
[8]   MEASUREMENTS OF ATOMIC SODIUM IN FLAMES BY ASYNCHRONOUS OPTICAL-SAMPLING - THEORY AND EXPERIMENT [J].
FIECHTNER, GJ ;
KING, GB ;
LAURENDEAU, NM ;
LYTLE, FE .
APPLIED OPTICS, 1992, 31 (15) :2849-2864
[9]   EFFICIENT FREQUENCY DOUBLING FOR SYNCHRONOUSLY MODE-LOCKED DYE-LASERS [J].
FIECHTNER, GJ ;
KING, GB ;
LAURENDEAU, NM ;
KNEISLER, RJ ;
LYTLE, FE .
APPLIED SPECTROSCOPY, 1989, 43 (07) :1286-1287
[10]  
FIECHTNER GJ, 1994, APPL OPTICS, V33, P1108