CONTINUOUS CARDIAC-OUTPUT MEASUREMENTS IN THE PERIOPERATIVE PERIOD

被引:27
作者
JAKOBSEN, CJ
MELSEN, NC
ANDRESEN, EB
机构
[1] Department of Anaesthesia, Skejby University Hospital, Aarhus
关键词
CARDIAC OUTPUT; CONTINUOUS MEASUREMENT; THERMODILUTION TECHNIQUE; ANESTHESIA; GENERAL; EPIDURAL;
D O I
10.1111/j.1399-6576.1995.tb04104.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Management of critically ill patients is based on knowledge of fundamental physiologic variables. Automatized and continuous measurement of these variables is preferable. A new system based upon the thermodilution method has been developed to measure cardiac output automatically and continuously. We evaluated the system in the potentially unstable perioperative period with possible great and rapid changes in cardiac output. Twenty patients, scheduled for open heart or abdominal aortic aneurysm surgery, were included in the study, which was approved by the local ethical committee. The patients were monitored up to 30 hours. At random intervals five, iced, bolus thermodilution cardiac output (BCO) determinations were made and compared to the continuous cardiac output measurements (CCO). Two hundred and thirty-one pairs of data were obtained. The cardiac outputs ranged from 2.5-14.9 l . min(-1). The absolute bias was 0.31 l . min(-1) (95% limits of agreement -1.4 l . min(-1) to 2.0 l . min(-1)). The mean relative error was 4.7% with a standard deviation of the relative error of 15.4%. The linear regression was represented by: CCO=1,1352 . BCO-0.36. The correlation coefficient R was 0.90 (P<0.001). In conclusion, the CCO measurement technique is a promising clinical method. The method is straightforward, requires no calibration, is independent of vascular geometry and measures with its limitations volumetric Bow. Finally automatic and continuous patient monitoring provides more information and has potential to reveal previously undetected haemodynamic events.
引用
收藏
页码:485 / 488
页数:4
相关论文
共 20 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   CARDIAC-OUTPUT BY THERMODILUTION TECHNIQUE - EFFECT OF INJECTATES VOLUME AND TEMPERATURE ON ACCURACY AND REPRODUCIBILITY IN THE CRITICALLY ILL PATIENT [J].
ELKAYAM, U ;
BERKLEY, R ;
AZEN, S ;
WEBER, L ;
GEVA, B ;
HENRY, WL .
CHEST, 1983, 84 (04) :418-422
[3]  
FITZGERALD DC, 1989, ANESTHESIOLOGY, V71, pA3
[4]  
FITZGERALD DC, 1989, ANESTHESIOLOGY, V71, pA386
[5]   NEW TECHNIQUE FOR MEASUREMENT OF CARDIAC OUTPUT BY THERMODILUTION IN MAN [J].
GANZ, W ;
DONOSO, R ;
MARCUS, HS ;
FORRESTER, JS ;
SWAN, HJC .
AMERICAN JOURNAL OF CARDIOLOGY, 1971, 27 (04) :392-+
[6]   Simultaneous determination of the pulmonary and systemic circulation times in man and of a figure related to the cardiac output [J].
Hamilton, WF ;
Moore, JW ;
Kinsman, JM ;
Spurling, RG .
AMERICAN JOURNAL OF PHYSIOLOGY, 1928, 84 (02) :338-344
[7]   Studies on the circulation IV. Further analysis of the injection method, and of changes in hemodynamtcs under physiological and pathological conditions [J].
Hamilton, WF ;
Moore, JW ;
Kinsman, JM ;
Spurling, RG .
AMERICAN JOURNAL OF PHYSIOLOGY, 1932, 99 (03) :534-551
[8]   A MULTICENTER STUDY OF PHYSICIANS KNOWLEDGE OF THE PULMONARY-ARTERY CATHETER [J].
IBERTI, TJ ;
FISCHER, EP ;
LEIBOWITZ, AB ;
PANACEK, EA ;
SILVERSTEIN, JH ;
ALBERTSON, TE .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1990, 264 (22) :2928-2932
[9]  
JANSEN JRC, 1990, UPDATE INTENSIVE CAR, P408
[10]   INTEROBSERVER VARIABILITY IN THE INTERPRETATION OF PULMONARY-ARTERY CATHETER PRESSURE TRACINGS [J].
KOMADINA, KH ;
SCHENK, DA ;
LAVEAU, P ;
DUNCAN, CA ;
CHAMBERS, SL .
CHEST, 1991, 100 (06) :1647-1654