NONCONTACT TEMPERATURE-MEASUREMENT .1. INTERPOLATION BASED TECHNIQUES

被引:122
作者
KHAN, MA [1 ]
ALLEMAND, C [1 ]
EAGAR, TW [1 ]
机构
[1] MIT,CAMBRIDGE,MA 02139
关键词
EMISSIVITY; ERRORS; PYROMETERS; SENSITIVITY; SIGNAL−TO−NOISE RATIO; TEMPERATURE MEASUREMENT; WAVELENGTHS;
D O I
10.1063/1.1142133
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Various ratio pyrometry techniques (two, three, and four color) are analyzed and shown to possess hitherto unknown sources of error under certain conditions. These conditions are shown to arise quite frequently. The ratio method is shown to be better suited to the shorter wavelengths. It has been shown, for various emissivities, that the predicted temperature has an asymptote at some wavelength. Ratio pyrometry methods are shown to be very sensitive to measurement noise and this sensitivity grows quickly with the number of terms in the ratio. The effect of a reference temperature in the system is examined and it is shown that under certain conditions this reference temperature can be used to make accurate predictions regarding the temperature elsewhere in the system even if the emissivity changes.
引用
收藏
页码:392 / 402
页数:11
相关论文
共 16 条
[1]   MULTI-WAVELENGTH PYROMETRY [J].
COATES, PB .
METROLOGIA, 1981, 17 (03) :103-109
[2]   RADIATING CHARACTERISTICS OF TUNGSTEN AND TUNGSTEN LAMPS [J].
FORSYTHE, WE ;
ADAMS, EQ .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1945, 35 (02) :108-113
[3]  
Gubareff G.G., 1960, THERMAL RAD PROPERTI
[4]  
Hiernaut J.-P., 1986, High Temperatures - High Pressures, V18, P627
[5]  
Hiernaut J.-P., 1986, High Temperatures - High Pressures, V18, P617
[6]  
Howell J.R., 1981, THERMAL RAD HEAT TRA
[7]  
HUNTER GB, 1984, THESIS MIT CAMBRIDGE
[8]   SPECTRAL EMISSIVITY OF TUNGSTEN [J].
LARRABEE, RD .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1959, 49 (06) :619-625
[9]  
MORI T, 1971, IRON STEEL, V57, P1198
[10]   REVIEW OF MULTICOLOUR PYROMETRY FOR TEMPERATURES BELOW 1500 DEGREES C [J].
REYNOLDS, PM .
BRITISH JOURNAL OF APPLIED PHYSICS, 1964, 15 (05) :579-&