MATERIAL PARAMETERS AND STRESS PROFILES WITHIN THE PERIODONTAL-LIGAMENT

被引:81
作者
ANDERSEN, KL
PEDERSEN, EH
MELSEN, B
机构
关键词
D O I
10.1016/S0889-5406(05)81576-8
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
Levels and profiles of initial stress in the periodontal ligament after application of various force systems were studied. Two finite-element models, based on sections of human autopsy material, were developed to simulate one full and one partial mandible. The validity of the finite-element model was improved by identification of material parameters; the mechanical properties of the tissue were described by means of strain-gauge measurements of initial tooth movements in human autopsy material. The multiple modeling technique, in which data from a coarse global model are transferred to a more detailed one, was used to identify bone structure and boundary conditions. Parameters known to influence the results were varied to establish the validity of the finite-element model. Iterative calculation methods were used to gain stable results. However, optimizing features of the bone structure and boundary conditions did not influence the results significantly. The elastic stiffness of the periodontal ligament was determined to 0.07 MPa and tau = 0.49 (tau being the Poisson's ratio). Stress profiles were obtained for various force systems - as in tipping, translation, and root movement. As we expected, there was a marked variation in the stress distribution from cervix to apex when tipping forces were applied. Bodily movement of the tooth produced an almost uniform stress distribution; root movement produced stress patterns opposite to those observed during tipping; and masticatory forces alone produced stress almost identical to those achieved by masticatory force in combination with orthodontic forces.
引用
收藏
页码:427 / 440
页数:14
相关论文
共 51 条
[1]
MAXIMUM FORCES AND DEFLECTIONS FROM ORTHODONTIC APPLICANCES [J].
BURSTONE, CJ ;
GOLDBERG, AJ .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1983, 84 (02) :95-103
[2]
HOLOGRAPHIC MEASUREMENT OF INCISOR EXTRUSION [J].
BURSTONE, CJ ;
EVERY, TW ;
PRYPUTNIEWICZ, RJ .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1982, 82 (01) :1-9
[3]
HOLOGRAPHIC DETERMINATION OF CENTERS OF ROTATION PRODUCED BY ORTHODONTIC FORCES [J].
BURSTONE, CJ ;
PRYPUTNIEWICZ, RJ .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1980, 77 (04) :396-409
[4]
HOLOGRAPHIC MEASUREMENT OF TOOTH MOBILITY IN 3 DIMENSIONS [J].
BURSTONE, CJ ;
PRYPUTNIEWICZ, RJ ;
BOWLEY, WW .
JOURNAL OF PERIODONTAL RESEARCH, 1978, 13 (04) :283-294
[5]
COMPRESSIVE BEHAVIOR OF BONE AS A 2-PHASE POROUS STRUCTURE [J].
CARTER, DR ;
HAYES, WC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) :954-962
[6]
CARTER DR, 1978, CLIN ORTHOP RELAT R, V135, P192
[7]
CENTERS OF ROTATION WITHIN PERIODONTAL SPACE [J].
CHRISTIANSEN, RL ;
BURSTONE, CJ .
AMERICAN JOURNAL OF ORTHODONTICS, 1969, 55 (04) :353-+
[8]
A 3-DIMENSIONAL FINITE-ELEMENT ANALYSIS OF A POROUS ROOTED CO-CR-MO ALLOY DENTAL IMPLANT [J].
COOK, SD ;
WEINSTEIN, AM ;
KLAWITTER, JJ .
JOURNAL OF DENTAL RESEARCH, 1982, 61 (01) :25-29
[9]
CURREY J, 1984, MECHANICAL ADAPTIONS
[10]
ELECTRIC CURRENTS, BONE REMODELING, AND ORTHODONTIC TOOTH MOVEMENT .2. INCREASE IN RATE OF TOOTH MOVEMENT AND PERIODONTAL CYCLIC-NUCLEOTIDE LEVELS BY COMBINED FORCE AND ELECTRIC-CURRENT [J].
DAVIDOVITCH, Z ;
FINKELSON, MD ;
STEIGMAN, S ;
SHANFELD, JL ;
MONTGOMERY, PC ;
KOROSTOFF, E .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1980, 77 (01) :33-47